Provide security alarms at access doors or hatches tied into the SCADA system.<br />

To the extent practicable, do not allow site features where unauthorized persons or<br />

materials can be easily concealed, such as structures, trees, or vegetation.<br />

5.9.9.2 Personnel Access and Safety<br />

A. Access<br />

The design of access features for storage facilities should address the following:<br />

Vehicular access to hatches and ladders is required and must be sized to<br />

accommodate the size of the vehicles normally used in maintenance or<br />

inspection of the facility.<br />

Ladders, stairways, and catwalks designed to conform to OSHA requirements.<br />

Hatches placed to facilitate ease of maintenance and cleaning.<br />

Hatches sized to accommodate access for personnel with tools, inspection<br />

divers, and remotely operated vehicle (ROV) inspection/cleaning equipment. For<br />

larger facilities, this requirement typically results in one or more large<br />

equipment hatches, through which field equipment can be lowered, and one or<br />

more personnel access hatches.<br />

Provide ladders or stairways inside of storage cells.<br />

Ladders should be caged and have climbing or fall protection.<br />

B. Egress and Emergency Escape<br />

The following are egress and emergency escape features:<br />

5.9.9.3 O&M<br />

A. Lighting<br />

B. Ventilation<br />

Provide internal and external restraint support/safety equipment.<br />

Ensure unobstructed clearances to access/egress points.<br />

Provide any other features necessary to meet requirements associated with<br />

confined-space entries.<br />

Permanent lighting fixtures should be provided to light hatch doors into storage<br />

cells and vaults and to provide visibility to the local work area perimeter.<br />

Permanent lighting fixtures should be provided to provide a minimum<br />

acceptable level of lighting within storage cells and vaults for routine<br />

inspections and maintenance.<br />

Power outlets should be easily accessible to all hatches for the operation of<br />

temporary lights within storage cells and vaults.<br />

Convenience outlets should within 6 feet of all mechanical equipment.<br />

5-60 SPU Design Standards and Guidelines