11.11.2014 Views

Pipelaying Tender-VOL IV - WorleyParsons.com

Pipelaying Tender-VOL IV - WorleyParsons.com

Pipelaying Tender-VOL IV - WorleyParsons.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

REWARI KANPUR PIPELINE<br />

PROJECT<br />

SUBMERGED ARS WELDED HELICAL<br />

SEAM (SAWH) LINE PIPE<br />

DOCUMENT NUMBER<br />

0068-00-SPC-2003<br />

Revision 0<br />

G.3.4.2 The test specimens, testing procedure, and rating of the specimens shall be in<br />

accordance<br />

(New) with API RP 5L3. The type of notch (pressed or chevron) shall be selected by agreement<br />

between the manufacturer and the purchaser.<br />

G.3.4.3 At least 80% of the heats shall exhibit a fracture appearance shear area of 75% or more<br />

(New) for the specified test temperature.<br />

G.3.4.4 In the event the average value of the two specimens from the length selected to represent<br />

(New)<br />

the lot is less than 75%, the manufacturer may elect to establish the lot average by testing<br />

two specimens from each of two or more additional lengths of pipe in the lot. In<br />

establishing the new lot average, the manufacturer may elect (a) to employ the <strong>com</strong>bined<br />

average of the three tests or more; or (b) to discard the result of the first test, reject the<br />

pipe from which it was taken, and employ the <strong>com</strong>bined average of the two or more<br />

additional tests. Alternatively, the manufacturer may elect to test all the pipe in the lot, in<br />

which case 80% or more of the lengths tested and applied to the order shall exhibit an<br />

average of 75% or more shear.<br />

G.3.4.5 Specimens showing material defects or defective preparation, whether observed before or<br />

(New)<br />

after breaking, may be discarded, and replacements shall be considered as original<br />

specimens.<br />

G.3.4.6 The manufacturer shall be responsible for replacement of such heats as may be<br />

(New) necessary to meet the above requirements.<br />

G.4 TEST FREQUENCY<br />

G.4.1<br />

G.4.2<br />

This clause is cancelled.<br />

Frequency of CVN and DWT for D <br />

specification (Refer Table 18).<br />

G.6 GUIDANCE FOR DETERMINING CVN ABSORBED ENERGY VALUES IN BURIED<br />

ONSHORE GAS PIPELINES<br />

G.6.1<br />

This clause is also applicable for liquid or liquefied petroleum gas(LPG) pipelines.<br />

G.12 ADDITIONAL FRACTURE TOUGHNESS REQUIREMENTS (TRANSVERSE CHARPY<br />

V-NOTCH) FOR PSL2 PIPE.<br />

G.12.1 Fracture toughness testing shall be performed in accordance with the requirements of<br />

(New) para 10.2.4.3 and 10.2.1.2 of API Spec 5L and as modified in this specification, with a<br />

test temperature of 32°F (0°C) or at a lower temperature as specified in the Purchase<br />

Order. The required minimum all heat average full size absorbed energy value (based on<br />

a set of three specimens) for transverse body specimen shall be the greater of (a) and<br />

(b) given below.<br />

The required minimum average full size absorbed energy value for weld and HAZ<br />

specimen shall also be the greater of (a) and (b) given below. In addition, the lowest<br />

individual absorbed energy value of the three specimens shall not be less than 80% of the<br />

value specified.<br />

0068-FMT-01 Page 32 of 41<br />

Copyright L&T-GULF Private Limited. All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!