EPMC SERVICES FOR REWARI – KANPUR PIPELINE<br />

SPECIFICATION FOR PIPELINE HYDRO TESTING<br />

SUBCONTRACTOR<br />

The party(s) which carry(s) out all or part of the design,<br />

procurement, installation and testing of the System(s) as<br />

specified by the CONTRACTOR.<br />

ASSEMBLY<br />

An arrangement of pre-fabricated pipes and/or<br />

<strong>com</strong>ponents such as a special crossing, SV Stations,<br />

Scraper trap block valve station or riser<br />

BLOCK VALVE (SV Station)<br />

A valve for interrupting the flow or to shut-in a section of a<br />

pipeline. A block valve is normally either fully opened or<br />

fully closed.<br />

GOLDEN WELD<br />

A weld which is not subject to a hydrostatic pressure test<br />

and as such must pass additional non-destructive testing<br />

inspection.<br />

HYDROSTATIC PRESSURE TEST<br />

LINE-FILL WATER<br />

That part of the hydrostatic pressure testing operations<br />

during which the test section is pressurized. The<br />

hydrostatic pressure test includes a strength test and a<br />

leak tightness test.<br />

Fresh water, chemically treated if required, used as the<br />

medium to fill and pressurize test sections.<br />

PRE-TEST<br />

A hydrostatic pressure test carried out on part or all of an<br />

assembly prior to final installation.<br />

n:\513-mh-2145-rkpl\11 engineering\11.8 pipelines\06 spec\specification for pipeline hydrotesting\mh2145-c000-<br />

pl-spc-0011.doc<br />

MH2145-C000-PL-SPC-0011 RevA Page 6 of 71