EPMC SERVICES FOR REWARI – KANPUR PIPELINE<br />

SPECIFICATION FOR PIPELINE HYDRO TESTING<br />

Location and method of water abstraction [----]<br />

Independent testing laboratory details [----]<br />

Water analysis report [----]<br />

Chemical treatment and injection rates, if appropriate [----]<br />

Dyes and injection rates, if appropriate [----]<br />

Location and method of water discharge/disposal [----]<br />

Section Activity/Procedure Requiring Information Covered<br />

Details of winter testing, if appropriate [----]<br />

Abstraction and discharge permits from the local<br />

authorities<br />

[----]<br />

11.0 Test Equipment<br />

Test equipment list, including performance of pumps<br />

and <strong>com</strong>pressors<br />

Specification and certification of temporary fittings and<br />

<strong>com</strong>ponents (piping, scraper traps, test heads, flexible<br />

hoses and connectors, etc.)<br />

[ " " ]<br />

[----]<br />

[----]<br />

Anchoring method for flexible hoses<br />

[ " " ]<br />

n:\513-mh-2145-rkpl\11 engineering\11.8 pipelines\06 spec\specification for pipeline hydrotesting\mh2145-c000-<br />

pl-spc-0011.doc<br />

MH2145-C000-PL-SPC-0011 RevA Page 53 of 71