EPMC SERVICES FOR REWARI – KANPUR PIPELINE<br />

SPECIFICATION FOR PIPELINE HYDRO TESTING<br />

• Cleaning<br />

• Gauging<br />

• Filling and chemical dosing<br />

Preparation for Hydrostatic Test:<br />

• Temperature Stabilization<br />

• Pressurizing<br />

• Air Content Check<br />

Hydrostatic Test:<br />

• Strength Test<br />

• Leak Tightness Test — 80% of strength test pressure<br />

• Testing of "Special" Test Sections — As per clause 10.4<br />

• Documentation - Test Validation Records<br />

Post-Testing Activities:<br />

• De-pressurizing<br />

• De-watering<br />

• Swabbing<br />

• Drying<br />

• Documentation<br />

Rectification Activities, if required:<br />

• Leak Locating During Test<br />

n:\513-mh-2145-rkpl\11 engineering\11.8 pipelines\06 spec\specification for pipeline hydrotesting\mh2145-c000-<br />

pl-spc-0011.doc<br />

MH2145-C000-PL-SPC-0011 RevA Page 13 of 71