REWARI KANPUR PIPELINE<br />

PROJECT<br />

HIGH FREQUENCY ELECTRIC WELDED<br />

(HFW) LINE PIPE<br />

DOCUMENT NUMBER<br />

0068-00-SPC-2002<br />

Revision 0<br />

Note: k (New)<br />

V+Nb+Ti shall not exceed 0.15%<br />

Cu+Ni shall not exceed 0.40%<br />

Al/N ratio shall be min. 2<br />

Note: l (New)<br />

If alloying elements other than those specified in Table 5 above are added to the steel, the<br />

limits of the additional <strong>com</strong>ponents shall be agreed with the Purchaser.<br />

Note: m (New)<br />

Minimum for Silicon is not applicable for Aluminium killed steel.<br />

For heat analysis and product analysis, all the elements listed in Table 5 of this<br />

specification shall be analysed and reported, even if those are not purposely added but are<br />

present as residuals only.<br />

9.2.4 Boron content shall be considered in CE (Pcm) formula even if it is less than 0.0005%.<br />

For pipes of all grades, size and wall thickness, Carbon Equivalent shall <strong>com</strong>ply with the<br />

following limits:<br />

CE (Pcm) 0.20<br />

9.2.5 For pipes of all grades, size and wall thickness, Carbon Equivalent shall <strong>com</strong>ply with the<br />

following limits:<br />

CE (IIW) 0.40<br />

9.3 TENSILE PROPERTIES<br />

The tensile tests and properties shall conform to the requirements of API 5L for the grade<br />

of pipe specified on the purchase order and as modified herein.<br />

The actual yield strength shall be as close as possible to the specified minimum yield<br />

strength (SMYS) but in no case it shall exceed the limits specified here under:<br />

API Spec 5L Grade<br />

Permissible in excess of SMYS, psi (MPa)<br />

Up to and including X46 19,000 (131)<br />

X52 to X65 22,000 (152)<br />

X70 20,000 (138)<br />

The ratio of body yield strength and body ultimate tensile strength of each test pipe on<br />

which body yield strength and body ultimate tensile strength are determined, shall not<br />

exceed 0.90.<br />