EPMC SERVICES FOR REWARI–KANPUR PIPELINE<br />

SPECIFICATION FOR PIPELINE BARRED TEE<br />

5. INSPECTION AND TESTING<br />

5.1 Non-destructive testing<br />

All personnel performing Non-destructive Tests (NDT) shall be qualified in the technique<br />

applied, in accordance with ASNT-TC-1A Level II by a third party, or equivalent approved by<br />

the OWNER. Original certificates shall be made available for inspection by Owner's<br />

REPRESENTAT<strong>IV</strong>E at the Vender's / Contractor's premises, if required. Personnel<br />

interpreting results of any non-destructive testing shall be qualified by a third party to SNT-<br />

TC-1A, levels II or III.<br />

All Non-destructive testing (NDT) shall be performed in accordance with written procedures.<br />

These procedures shall have the prior approval of the OWNER. NDT shall be carried out on<br />

tees after all mechanical testing and manufacturing stages and any heat treatment have been<br />

<strong>com</strong>pleted.<br />

5.2 Visual Inspection<br />

100% Visual Inspection The body of every fitting shall be examined internally and externally<br />

for surface defects. The surfaces of the fittings shall be free from all dents, gouges, laps,<br />

score marks, arc strikes, laps, undercuts or other detrimental defects. Welds shall be<br />

inspected for 100% of the length, both outside and inside. The requirements of Workmanship<br />

and defects shall be as per the connected line pipe specification. Defects shall be removed by<br />

grinding or by weld repair, except that weld repair is not allowed on the body of the tee. Weld<br />

repairs shall be qualified and carried out in accordance with the applicable line pipe<br />

specification.<br />

5.3 Non-destructive testing of fittings shall include:<br />

• 100 percent radiographic testing of all seam welds. Radiography of seam welds shall<br />

be in accordance with ASME VIII Div 1, Clause UW - 51. For butt welds in tees, with a<br />

thickness greater than 20 mm (0.8 inches), radiographic inspection may be replaced<br />

by ultrasonic inspection, at the discretion of owner.<br />

For the acceptance of radiographic films, the technique used shall result in sensitivity<br />

better than 2% of the thickness of the weld metal and a relative film density of 2.0 to<br />

3.5 in the weld metal.<br />

n:\513-mh-2145-rkpl\11 engineering\11.8 pipelines\06 spec\specification for pipeline barred tee\mh2145-c000-plspc-0008.doc<br />

EV<br />

MH2145-C000-PL-SPC-0008 RevA Page 13 of 25