Testing RM Readers<br />
To test the inputs of the RM reader:<br />
17. Press the 6 key to test supervised input number 1.<br />
18. Use resistors across the inputs to simulate the conditions listed in the<br />
following table and check the LED responses.<br />
Table C.1: LED Indications<br />
LED Response<br />
Green LED lights<br />
Amber LED lights<br />
Red LED lights<br />
Red LED flashes slowly<br />
Red LED flashes rapidly<br />
Condition<br />
Input is in secure condition (1K)<br />
Input is in alarm condition (500Ω)/ (2KΩ)<br />
Line fault<br />
Input is open (open)<br />
Input is shorted (shorted)<br />
19. Press the 7 key to test supervised input number 2. The LED responses<br />
indicate the conditions listed in the previous table.<br />
To test the tamper switch of the RM reader:<br />
20. Set SW3-4 (Tamper Override) to OFF (Open)<br />
21. Press the 8 key to test the tamper switch. If the tamper switch is<br />
depressed, the red LED is off. When the switch is released, the red LED<br />
lights up.<br />
Turn off Test Mode:<br />
22. When the RM reader completes the tests, turn off Test Mode by<br />
returning the address switch to its original address setting.<br />
C-4 <strong>apC</strong>/<strong>8X</strong> Installation and Configuration Guide