The <strong>apC</strong>Test Program<br />
The first line displayed in Figure C.7 shows a Wiegand 26 card with Facility<br />
Code 204 and a card number of 27445.<br />
0 11001100 011010110011010 0<br />
Even<br />
parity<br />
Facility Code = 204 Card Number = 27445<br />
Odd<br />
parity<br />
Figure C.8: Wiegand 26 Sample Card Data<br />
Test LED<br />
The Test LED operation is no longer supported.<br />
Test CtlPts<br />
The Test CtlPts (Control Points) menu allows you to activate relays<br />
associated with the <strong>apC</strong>. You can activate individual relays or all at once. You<br />
can cycle through all of them one at a time at a frequency that is configured.<br />
• Use F3 and F4 to select control points<br />
• Use F5 (Set), F6 (Reset), or F7 (Cycle) to control the control points<br />
• Use F8 to control the cycle duration<br />
Note:<br />
When you exit from the control points menu, the control points<br />
will remain in the state in which you set them. When you exit the<br />
<strong>apC</strong> Test utility, the control points return to a non activated state.<br />
Test Mptsts<br />
The Monitor Point test will display the state of selected monitor points<br />
dynamically.<br />
• Use F3 to display monitor points 1-16<br />
• Use F4 to display monitor points 17-32<br />
• Use F5 to display monitor points 33-48<br />
• Use F6 to display monitor points 49-64<br />
C-16 <strong>apC</strong>/<strong>8X</strong> Installation and Configuration Guide