Wiring Card Readers<br />

<strong>apC</strong>/<strong>8X</strong><br />

Reader<br />

Port<br />

1<br />

2<br />

3<br />

4<br />

+12V<br />

+TXD/+RXD<br />

-TXD/-RXD<br />

GND<br />

Two-wire RS-485 with<br />

shield and drain wire<br />

Reader<br />

1<br />

Reader<br />

2<br />

Reader<br />

3<br />

Reader<br />

4<br />

Reader<br />

5<br />

Reader<br />

6<br />

Last reader must be terminated using<br />

SW3-5 (RM-4) or SW5-5 (RM-4E)<br />

Figure B.2: Connecting the <strong>apC</strong>/<strong>8X</strong> and Readers in a Daisy Chain Configuration<br />

Note:<br />

The last reader in the chain is the one located electrically furthest<br />

from the <strong>apC</strong>/<strong>8X</strong>. In Figure B.2, the last reader in the chain is<br />

Reader 6. Make sure that SW3-5 (RM-4) or SW5-5 (RM-4E) is<br />

closed (On) on Reader 6.<br />

For all RM readers, except the last one in the chain: Make sure switch SW3-5<br />

(RM-4) or SW5-5 (RM-4E) is open (Off).<br />

See Appendix G for detailed wiring diagrams.<br />