<strong>apC</strong>/<strong>8X</strong> Panel Setup<br />
Table 5.1: <strong>apC</strong>/<strong>8X</strong> DIP Switch Settings<br />
Switch<br />
Setting<br />
(* = Default)<br />
System Feature<br />
S2 S2:1 a ON<br />
OFF*<br />
S2:2 a ON<br />
OFF*<br />
S2:3 a ON<br />
OFF*<br />
S2:6 b ON<br />
OFF*<br />
S2:7 ON<br />
OFF*<br />
S2:8 ON<br />
OFF*<br />
S3 S3:1 b ON<br />
OFF*<br />
S3:2 ON<br />
OFF*<br />
S3:3 b ON<br />
OFF*<br />
S3:4 b ON<br />
OFF*<br />
S3:5 b ON<br />
OFF*<br />
S3:6 b ON<br />
OFF*<br />
S3:7 ON<br />
OFF*<br />
S3:8 b ON<br />
OFF*<br />
Relay link on when door forced open<br />
No link when door forced open<br />
Relay link on when door held<br />
No link when door held<br />
Relay link on when <strong>apC</strong>/<strong>8X</strong> is offline<br />
No link when <strong>apC</strong>/<strong>8X</strong> is offline<br />
Reader keypad for PIN entry, if enabled<br />
Keypad for elevator floor selection, if enabled<br />
<strong>apC</strong>/<strong>8X</strong> ignores card misreads<br />
<strong>apC</strong>/<strong>8X</strong> reports misreads<br />
AUX port for local printout<br />
AUX port for <strong>apC</strong>/<strong>8X</strong> test program<br />
Card entry through keypad enabled<br />
Card entry through keypad not enabled<br />
Optional LED access pattern enabled at reader<br />
Normal LED access pattern enabled at reader<br />
Card numbers less than or equal to 65535 (16 bit)<br />
Card numbers greater than 65535 (32 bit)<br />
Activate/deactivate dates are stored<br />
Activate/deactivate dates are not stored<br />
Space reserved in card record for local anti-passback<br />
No space reserved in card record for local anti-passback<br />
Space reserved in card record for elevator control<br />
No space reserved in card record for local elevator control<br />
Magnetic stripe encryption used<br />
No Magnetic stripe encryption used<br />
Reverse card swipe signals duress<br />
Duress alarm disabled<br />