Testing the <strong>apC</strong>/<strong>8X</strong> Installation<br />
RM LEDs<br />
Each RM reader has three LEDs: red, green, and amber. Table C.2 describes<br />
the various conditions indicated by the RM LEDs.<br />
Table C.2: RM Reader LED Indications<br />
Red LED Amber Green Indication<br />
Brief flash Brief flash Brief flash Power up<br />
Off Off Off Online (Alternate indication)*<br />
Off On Off Online (Normal indication)*<br />
On Off Off Offline or reader tamper<br />
Solid for 1 sec. Off Off Access denied (Normal indication)*<br />
Fast flash for 2 sec. Off Off Access denied (Alternate indication)*<br />
Off Off On Access granted or door unlocked<br />
(Alternate indication)*<br />
Off Off Fast flash Access granted (Normal indication)*<br />
Off Off Slow flash Door unlocked (Normal indication)*<br />
Off Slow flash Off Enter second card (escorted access only)<br />
Off Fast flash Off Enter PIN<br />
Off Fast flash Off Enter floor # (systems configured for<br />
elevator control only)<br />
Flash w/ each key<br />
press<br />
Off Flash w/ each key press Keypad input<br />
Slow flash Off Off Reader not configured<br />
Fast flash Fast flash Fast flash Alarm: door forced/held open<br />
On On On Error condition: Remove power to prevent<br />
damage to RM<br />
Note:<br />
*To set Reader LEDs to Normal (default) or Alternate<br />
indications, select Diagnostics System (Diag) utility> Dialup ><br />
ReaderLEDSettings > Entry Value = 0 (normal) or 3 (alternate).<br />
<strong>apC</strong>/<strong>8X</strong> Installation and Configuration Guide C-5