Connecting to a Host Computer<br />

Connecting to a Host Computer<br />

The host port P32 connects the <strong>apC</strong>/<strong>8X</strong> to a host computer (see Figure 4.1).<br />

• A single <strong>apC</strong>/<strong>8X</strong> can connect to the host via an RS-232 serial<br />

connection.<br />

• Multiple <strong>apC</strong>/<strong>8X</strong>s communicate via an RS-485 chain, but the <strong>apC</strong>/<strong>8X</strong><br />

chain must communicate with the host through an RS-232 to RS-485<br />

converter.<br />

<strong>apC</strong>/<strong>8X</strong><br />

Host<br />

port<br />

P32<br />

1<br />

2<br />

3<br />

4<br />

5<br />

RS-232<br />

TX<br />

RX<br />

GND<br />

RX<br />

TX<br />

GND<br />

Host PC<br />

Twisted, shielded 22 AWG (.325 mm)<br />

Belden 9855 or equivalent<br />

Maximum 50 feet (15 meters) without modems or line drivers<br />

Figure 4.1: RS-232 Three-wire Connection between <strong>apC</strong>/<strong>8X</strong> and Host<br />

You can use modems, line drivers, or other communications devices to<br />

increase the distance between the host and the <strong>apC</strong>/<strong>8X</strong>.<br />

The following sections describe these connections:<br />

• RS-232<br />

• RS-485<br />

• Modems for dialup <strong>apC</strong>/<strong>8X</strong>s<br />

• Modems for directly connected <strong>apC</strong>/<strong>8X</strong>s<br />

4-2 <strong>apC</strong>/<strong>8X</strong> Installation and Configuration Guide