Smart Card Tab<br />
Add an iCLASS<br />
Definition<br />
1. Click the Smart Card tab.<br />
2. Click the Create new iCLASS button.<br />
3. Complete the fields on the screen. See the iCLASS Definition Fields table on page 50<br />
for more information.<br />
4. Click the Accept settings button.<br />
Edit an iCLASS<br />
Definition<br />
1. Click the Smart Card tab.<br />
2. Choose the iCLASS definition you want to edit from the drop-down box.<br />
3. Click the Edit selected iCLASS button.<br />
4. Complete the fields on the screen. See the iCLASS Definition Fields table on page 50<br />
for more information.<br />
5. Click the Accept settings button.<br />
Delete an<br />
iCLASS<br />
Definition<br />
1. Click the Smart Card tab.<br />
2. Choose the iCLASS definition you want to delete from the drop-down box.<br />
3. Click the Edit selected iCLASS button.<br />
4. Click the Delete this iCLASS definition check box.<br />
5. Click the Accept settings button.<br />
iCLASS<br />
Definition<br />
Fields<br />
Table 11-19: iClass Definition Fields<br />
Field Req’d Description<br />
iCLASS definition<br />
name<br />
Biometric template<br />
compression<br />
Enter “new” iClass<br />
key<br />
Confirm “new”<br />
iClass key<br />
Yes<br />
• Name of the iCLASS definition<br />
• Any name that distinguishes this definition from others<br />
• Controls the amount of compression of the finger<br />
template before it is written to the iCLASS card<br />
• Maximum compression should be used initially<br />
• See the iCLASS Card Compression table on page 51<br />
for more information<br />
• A password that encrypts the areas used by the<br />
readers on iCLASS cards<br />
• Protects the fingerprint data from being read if the<br />
same cards are used with other devices.<br />
• 16 hex digits (0–9 and A–F.)<br />
• A default key is used when a new iCLASS definition is<br />
defined. Can be used permanently if desired.<br />
• For increased security, change this key periodically.<br />
Confirmation of previous field<br />
50