ES/2 TEST SOFTWARE<br />

SynchroNet ES/2 <strong>Service</strong> <strong>Manual</strong><br />

COMMS TEST ROUTINES<br />

Tests 22, 23 and 24 are all associated with the comms processor. As discussed at the start of the<br />

test software section, the comms processor is requested to enter its test routines when the test<br />

software initialises. The comms LED should flash twice to indicate that it is waiting for a command<br />

from the fifo.<br />

There are 4 standard error screens associated with the comms/kernel processor interaction rather<br />

than the tests themselves. In these error screens pressing the re-run key (key 3) attempts to re-run<br />

the previous test and pressing the continue key (key 4) will continue with the test or return to the test<br />

select menu as appropriate.<br />

1) If the kernel has waited for a message from the comms which has not arrived then the<br />

following screen will be displayed:<br />

Timeout waiting for re-run ><br />

COMMS response Press to continue ><br />

2) If the kernel processor received data from the comms which did not match anything it was<br />

expecting then the following screen will be displayed:<br />

Bad data received re-run ><br />

from COMMS Press to continue ><br />

3) If the Comms processor received data from the kernel which did not match anything it<br />

was expecting then the following screen will be displayed:<br />

Bad data was received re-run ><br />

by COMMS Press to continue ><br />

4) If the Kernel processor attempts to send some data to the comms and fails because the<br />

fifo reports it is full then the following screen is displayed:<br />

FIFO1 is reporting it re-run ><br />

is full Press to continue ><br />

2:14 Issue 1