ES/2 TEST SOFTWARE<br />
SynchroNet ES/2 <strong>Service</strong> <strong>Manual</strong><br />
COMMS TEST ROUTINES<br />
Tests 22, 23 and 24 are all associated with the comms processor. As discussed at the start of the<br />
test software section, the comms processor is requested to enter its test routines when the test<br />
software initialises. The comms LED should flash twice to indicate that it is waiting for a command<br />
from the fifo.<br />
There are 4 standard error screens associated with the comms/kernel processor interaction rather<br />
than the tests themselves. In these error screens pressing the re-run key (key 3) attempts to re-run<br />
the previous test and pressing the continue key (key 4) will continue with the test or return to the test<br />
select menu as appropriate.<br />
1) If the kernel has waited for a message from the comms which has not arrived then the<br />
following screen will be displayed:<br />
Timeout waiting for re-run ><br />
COMMS response Press to continue ><br />
2) If the kernel processor received data from the comms which did not match anything it was<br />
expecting then the following screen will be displayed:<br />
Bad data received re-run ><br />
from COMMS Press to continue ><br />
3) If the Comms processor received data from the kernel which did not match anything it<br />
was expecting then the following screen will be displayed:<br />
Bad data was received re-run ><br />
by COMMS Press to continue ><br />
4) If the Kernel processor attempts to send some data to the comms and fails because the<br />
fifo reports it is full then the following screen is displayed:<br />
FIFO1 is reporting it re-run ><br />
is full Press to continue ><br />
2:14 Issue 1