SynchroNet ES/2 <strong>Service</strong> <strong>Manual</strong><br />

MACHINE PARAMETERS<br />

play command. Any overshoot in either of these cases causes an untidy and unacceptable<br />

performance. These parameters are best set in conjunction with CWRAMP described earlier.<br />

ULTIME $1057/8<br />

display : ULTIME<br />

When a video machine is chasing or locating it will attempt to unlace the tape and perform an<br />

unlaced wind if the difference to be made up is greater than this value. The ability to lace or unlace<br />

the tape is reflected in the command bytes ‘LACE’ $108d and ‘UNLACE’ $108e. This value is in<br />

BCD minutes and seconds (i.e. only use digits in the range 0-9), minutes in $1057 and seconds in<br />

$1058.<br />

LTIME $1059/a<br />

display : LTIME<br />

When a video machine is locating or chasing and the tape has previously been unlaced as<br />

described above then it will attempt to reduce the difference below this value before it will lace the<br />

tape up again. Conditions apply as for ULTIME, it is also BCD minutes and seconds (i.e. only use<br />

digits in the range 0-9).<br />

PRKWND $105b/c<br />

During a chase or locate operation when the machine gets within the toggle window it will use this<br />

speed to toggle into park ahead of the master reference. It is in IS Format. If this parameter is set to<br />

0 then the value of MINWND will be used for this operation.<br />

PRKJOG $105d<br />

Maximum number of attempts to get within PRKERR (1052) of the locate target. When parameter is<br />

set to 0 the default value of 3 is used.<br />

SVOWIN $105e<br />

This sets the number of frames away from lock that the machine must be before the servo system<br />

causes a chase operation to be started in order to rejoin the timeline. If this parameter is set to zero<br />

then a default value of 80 frames (50hex or 3secs 5frames @25fps) is used. Units are binary<br />

frames<br />

RESERVED $105f<br />