Chapter 13: Specifications<br />
SpO 2<br />
SpO 2 Range: 0 - 100% Functional Saturation (Display Maximum: 99%)<br />
SpO 2 Resolution: 1 count (%SpO 2 )<br />
SpO 2 Averaging: 4, 8, or 16 pulses (default = 8)<br />
SpO 2 Alarm limits:<br />
Calibration:<br />
Sensors:<br />
SpO 2 Accuracy:<br />
High: off and 99-51, 1 step (%SpO 2 ) increments.<br />
Low: 50-99, 1 step (%SpO 2 ) increments.<br />
Factory calibrated over range 70% to 100% SpO 2<br />
using human blood<br />
samples to functional saturation. Test methods are available upon request.<br />
No in-service calibration is required.<br />
Red: 660 nm, 2 mW (typical)<br />
Infrared: 905 nm, 2-2.4 mW (typical)<br />
70 to 100% SpO 2 , less than 70% SpO 2 is undefined.<br />
Sensor 6<br />
SpO 2 Accuracy in<br />
Normal Conditions 1<br />
SpO 2 Accuracy in<br />
Low Perfusion Conditions 1, 3<br />
BCI® 3044 ±2 2 ARMS ±2 2 ARMS<br />
SurgiVet® V1703 ±2.5 4 ARMS ±2.5 4 ARMS<br />
SurgiVet® V1707 ±2 4 ARMS ±2 4 ARMS<br />
SurgiVet® V3078 ±3.6 2, 5 ARMS ±3.6 2, 5 ARMS<br />
1<br />
Because pulse oximeter measurements are statistically distributed, only about two-thirds of pulse oximeter equipment<br />
measurements can be expected to fall within the ± A RMS of the value measured by the CO-oximeter.<br />
2<br />
The oximeter has been validated on 10 human adult volunteers that did not have health problems and were nonsmokers.<br />
The study was conducted at oxygen concentrations evenly distributed over an SpO 2 range of 70-100%.<br />
3<br />
<strong>Pulse</strong> Amplitude 1% to 0.1%. Tested using industry standard simulator.<br />
4<br />
Accuracy based on testing using industry standard simulator.<br />
5<br />
Accuracy based on equivalent BCI® 3078 sensor.<br />
6<br />
Accuracy of the V1700 reflectance sensor is unspecified.<br />
<strong>Pulse</strong> Rate<br />
<strong>Pulse</strong> Rate Range:<br />
<strong>Pulse</strong> Rate Resolution:<br />
20-350 bpm<br />
1 bpm<br />
<strong>Pulse</strong> Rate Averaging: 8 or 16 seconds (default = 8)<br />
<strong>Pulse</strong> Rate Alarm limits:<br />
High 350-21 bpm in 1 bpm increments<br />
Low 20-350 bpm in 1 bpm increments<br />
Sensor 5<br />
PR Accuracy in Normal<br />
Conditions 1<br />
PR Accuracy in<br />
Low Perfusion Conditions 1<br />
SurgiVet® V1703, V1707 ±2 ARMS ±2 2 ARMS<br />
SurgiVet® V3078 3 ±2 ARMS ±3 4 ARMS<br />
1<br />
Because pulse oximeter measurements are statistically distributed, only about two-thirds of pulse oximeter equipment<br />
measurements can be expected to fall within the ± A RMS of the value measured by the CO-oximeter.<br />
2<br />
<strong>Pulse</strong> Amplitude 1% to 0.1%. Tested using industry standard simulator.<br />
3<br />
Accuracy based on equivalent BCI® 3078 sensor.<br />
4<br />
<strong>Pulse</strong> Amplitude 1% to 0.3%. Tested using industry standard simulator.<br />
5<br />
Accuracy of the V1700 reflectance sensor is unspecified.<br />
13-2 Veterinary <strong>V1030</strong> <strong>Hand</strong>-<strong>Held</strong> <strong>Pulse</strong> <strong>Oximeter</strong> Operation Manual