11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 25<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2<strong>on</strong> the screen. If the beam moves in a different directi<strong>on</strong>, adjust the directi<strong>on</strong> with the Multifuncti<strong>on</strong> Yknob.Descripti<strong>on</strong>The beam shift has two comp<strong>on</strong>ents, an alignment value and a variable 'user' value. If properly aligned,the alignment value will have the beam centered <strong>on</strong> the screen. It then is <strong>on</strong>ly necessary to reset the'user' value to zero to have the beam back at the screen center.The alignment value for the beam shift is used frequently in alignment (any time the beam must becentered with Multifuncti<strong>on</strong> X,Y). In any such step, the 'user' value of the beam shift is always reset tozero. Therefore, <strong>on</strong> a properly aligned microscope, it is always possible to find the beam again simply byentering this alignment step: the 'user' value is reset to zero, so the beam should now be centered.5.9 Beam shift calibrati<strong>on</strong> HMPurpose: Calibrate the beam shift to physically meaningful values.Importance: CONVENIENCE.Method: Move the focused beam to the edge of the viewing screen with Multifuncti<strong>on</strong> X and adjust thedisplayed value of the image shift using Multifuncti<strong>on</strong> Y.ProcedureThe alignment procedure c<strong>on</strong>sists of four steps:• In the first step the beam is accurately centered <strong>on</strong> the screen.• In the sec<strong>on</strong>d step, the beam is shifted with Multifuncti<strong>on</strong> X to the edge of the viewing screen (thearea where the fluorescent material - yellow/green - stops and the aluminium substrate is visible).Then the displayed value for the beam shift is adjusted to the correct value with the Multifuncti<strong>on</strong> Y.• The third and fourth steps repeat the first and sec<strong>on</strong>d steps but now for the Y directi<strong>on</strong> of the beamshift.5.10 Beam tilt (dark field) calibrati<strong>on</strong> HMPurpose: Calibrate the beam tilt (dark field) to physically meaningful values.Importance: ESSENTIAL for meaningful beam tilt values in dark field.Method: Tilt the beam and adjust the displayed value of the beam tilt using Multifuncti<strong>on</strong> X,Y.ProcedureThe alignment procedure c<strong>on</strong>sists of five steps:• The first step is a preparati<strong>on</strong> step for the diffracti<strong>on</strong> mode.• In the sec<strong>on</strong>d step the diffracti<strong>on</strong> pattern must be centered accurately (<strong>on</strong> the center of the viewingscreen or the tip of the beam stop).• In the third step, the beam is tilted (this is, the diffracti<strong>on</strong> pattern is shifted) with Multifuncti<strong>on</strong> X tobring a ring to the center and the beam tilt value is adjusted with Multifuncti<strong>on</strong> Y to the correct value.• The fourth and fifth steps repeat the procedure of the sec<strong>on</strong>d and third steps for the Y diffracti<strong>on</strong>shift.Descripti<strong>on</strong>The beam tilt is c<strong>on</strong>verted through the calibrati<strong>on</strong> procedure into to physically meaningful units. Thebeam tilt can be read off in the flap-out of the Alignment C<strong>on</strong>trol Panel and is used in the Dark FieldC<strong>on</strong>trol Panel.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!