Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 33<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2ProcedureThe alignment procedure c<strong>on</strong>sists of three steps:• A preparati<strong>on</strong> step in which the image is focused.• A step in which the reference camera length (~500 mm) is focused and centered.• A step in which all other camera lengths are focused and centered.Notes:• The magnificati<strong>on</strong> system (projector lenses) is normalized when the magnificati<strong>on</strong> is changed tomake the diffracti<strong>on</strong> pattern positi<strong>on</strong> better reproducible.• For each camera length the focus setting is stored during this alignment.6.13 Align camera length MhPurpose: Determine the shift necessary for aligning the reference camera length when coming from Mhmagnificati<strong>on</strong>s, so that the diffracti<strong>on</strong> pattern remains in the center.Importance: CONVENIENCE for having the diffracti<strong>on</strong> patterns centered when the camera length ischanged.Method: Center the diffracti<strong>on</strong> pattern for the reference camera length (~500 mm), then align all cameralengths to the reference camera length. Focus all camera lengths.ProcedureThe alignment procedure c<strong>on</strong>sists of two steps :• A preparati<strong>on</strong> step in which the Mh image is focused.• A step in which the reference camera length (~500 mm) is focused and centered.Notes:• In principle, always go into diffracti<strong>on</strong> from an SA magnificati<strong>on</strong>, not from Mh magnificati<strong>on</strong> for properdiffracting c<strong>on</strong>diti<strong>on</strong>s.• For the Mh magnificati<strong>on</strong> camera lengths, <strong>on</strong>ly a single setting is needed, comparable to the SAdiffracti<strong>on</strong> alignment. The differences between individual camera lengths is handled by the samesettings as d<strong>on</strong>e in the SA camera length alignment. The need for a separate value is due to theseparati<strong>on</strong> of the diffracti<strong>on</strong> alignment for Mi <strong>on</strong> the <strong>on</strong>e hand (used for the cross-over shift) and SAand Mh.6.14 Image shift calibrati<strong>on</strong> HMPurpose: Calibrate the image shift to physically meaningful values.Importance: ESSENTIAL for meaningful image measurement results.Method: Move the focused beam to the edge of the viewing screen (the microscope uses the image shiftto do this) and adjust the displayed value of the image shift using Multifuncti<strong>on</strong> Y. The focused beam isthus used as a reference marker.ProcedureThe alignment procedure c<strong>on</strong>sists of four steps:• In the first step the beam is accurately centered <strong>on</strong> the screen.• In the sec<strong>on</strong>d step, the beam is shifted with Multifuncti<strong>on</strong> X to the edge of the viewing screen (thearea where the fluorescent material - yellow/green - stops and the aluminium substrate is visible).Then the displayed value for the image shift is adjusted to the correct value with the Multifuncti<strong>on</strong> Y.• The third and fourth steps repeat the first and sec<strong>on</strong>d steps but now for the Y directi<strong>on</strong> of the imageshift.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!