11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 63<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2ProcedureThe alignment procedure c<strong>on</strong>sists of five steps:• The first step is a preparati<strong>on</strong> step to center and focus the beam.• In the sec<strong>on</strong>d step a STEM image must be made of a cross-grating specimen.• In the third step the scan rotati<strong>on</strong> is set so the horiz<strong>on</strong>tal <strong>line</strong>s of the cross-grating are horiz<strong>on</strong>tal inthe STEM image. The rotati<strong>on</strong> required should be less than ~15° (see note below).• In the fourth step the distorti<strong>on</strong>s are adjusted. Multifuncti<strong>on</strong> X c<strong>on</strong>trols the trapezoid distorti<strong>on</strong> (thevertical <strong>line</strong>s of the grating are not perpendicular to the horiz<strong>on</strong>tal <strong>line</strong>s), while the Multifuncti<strong>on</strong> Yadjusts the relative strengths of the horiz<strong>on</strong>tal and vertical scans (rectangular distorti<strong>on</strong>).• A check <strong>on</strong> the previous alignment with the image rotated by 90°.If necessary, iterate steps three and four (see also notes below).Notes:• It is essential that the pivot point alignment has been d<strong>on</strong>e properly before the distorti<strong>on</strong> adjustmentis d<strong>on</strong>e.• The cross-grating used must be inserted into the microscope in such a way that the horiz<strong>on</strong>tal andvertical <strong>line</strong>s in the grating are roughly parallel to the horiz<strong>on</strong>tal and vertical in the image when thescan rotati<strong>on</strong> (and the default scan rotati<strong>on</strong>) is close to 0° (within ~15°), otherwise the alignment isvery difficult (requires many iterati<strong>on</strong>s). Judge whether the orientati<strong>on</strong> of the cross-grating is suitablein the sec<strong>on</strong>d or third step of the procedure. If the orientati<strong>on</strong> is further away from 0°, remove thespecimen holder from the microscope and rotate the specimen until its orientati<strong>on</strong> is suitable for thisalignment.• The distorti<strong>on</strong>s of the image may be judged more easily by drawing a square in the image. Click <strong>on</strong>the Image Selecti<strong>on</strong> Tool toolbar butt<strong>on</strong> in TIA , click in the top left quadrant of the image and dragthe cursor to bottom right while keeping the Shift key <strong>on</strong> the keyboard pressed down (the latter forcesthe image selecti<strong>on</strong> drawn to remain square). It is then easy to count the number of cross-gratingsquares in the horiz<strong>on</strong>tal and vertical dimensi<strong>on</strong>s and making sure that the numbers are the same.• Descripti<strong>on</strong>• The deflecti<strong>on</strong> coils used in the microscope are not all equal and exactly the same from <strong>on</strong>emicroscope to another. There are therefore alignment procedures that will result in adjustments thatcompensate for the variati<strong>on</strong> in the coils. For the deflecti<strong>on</strong> coils used in TEM operati<strong>on</strong>, the twoadjustable parameters are the pivot points and the perpendicular correcti<strong>on</strong>. The pivot adjusts for thedifference in strength between upper and lower coil (e.g the X coil). The perpendicular correcti<strong>on</strong>adjusts for a rotati<strong>on</strong> between the upper and lower coils (e.g. the upper and lower X coils) by addinga small deflecti<strong>on</strong> to the other lower coil (in that case the lower Y coil). For use in TEM this issufficient.• In STEM, however, additi<strong>on</strong>al adjustments are necessary, otherwise image distorti<strong>on</strong>s (stretch of <strong>on</strong>edirecti<strong>on</strong> relative to the other and angular distorti<strong>on</strong>) appear. These adjustments correct for thedifference in strength between the X and Y coils and for any deviati<strong>on</strong> from 90° between the X and Ycoils. In principle this can be d<strong>on</strong>e both for the upper and lower coils separately but in practice this istoo difficult to align and a single adjustment is sufficient.12.9 HM-STEM Default rotati<strong>on</strong>Purpose: Define the rotati<strong>on</strong> correcti<strong>on</strong> for STEM imaging.Importance: CONVENIENCE for having the STEM image (at 0° scan rotati<strong>on</strong>) in the same orientati<strong>on</strong>as the TEM image (<strong>on</strong> the viewing screen).Method: Observe the scan frame <strong>on</strong> the viewing screen and rotate it until it runs as described below.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!