11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 65<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 213 LM-STEM procedure13.1 LM-STEM Preparati<strong>on</strong>Purpose: Set up microscope for aligning the column in LM-STEM.Importance: CONVENIENCE as a reminder to set up the proper c<strong>on</strong>diti<strong>on</strong>s before starting the actualalignment.For STEM alignment a number of pre-c<strong>on</strong>diti<strong>on</strong>s must be met, otherwise no proper alignment can bed<strong>on</strong>e:• First of all, LM-STEM relies <strong>on</strong> a proper setting of several optical parameters for which the Gun, LMBeam and LM Image as well as HM-TEM Image alignment must have been d<strong>on</strong>e.• Sec<strong>on</strong>d, Tem Imaging & Analysis (TIA) must be running when for STEM alignment.• Third, the settings for the Preview view mode must be set so as to give an image size of 512x512pixels and a frame time of approximately 6 sec<strong>on</strong>ds and the Search view mode to an image size of256x256 and a frame time of approximately 3 sec<strong>on</strong>ds.• Finally, the Bright-Field (BF) detector must be selected (and all other detectors deselected) in theSTEM Detector C<strong>on</strong>trol Panel.Note: The diffracti<strong>on</strong> focus (LAD) is LM-STEM is kept as set in LAD (proceed to LM, then todiffracti<strong>on</strong>). In most cases this should be kept at the default setting. Unless there is a reas<strong>on</strong> todeviate from this, it is important to make sure the setting is properly d<strong>on</strong>e. Go to LM, then LADand press the Eucentric focus butt<strong>on</strong> to reset the LAD focus to the default value.13.2 LM-STEM Intensity presetPurpose: Set up Intensity setting for focused beam in LM-STEM.Importance: ESSENTIAL for proper setting for LM-STEM (Intensity settings).Method: First focus the image, then focus the beam.Important : During STEM alignment TIA (Tem Imaging & Analysis) must be running.ProcedureThe alignment procedure c<strong>on</strong>sists of three steps :• A first step in which the image is focused and the beam is centered.• A sec<strong>on</strong>d step in which the beam is focused accurately (sets the Intensity setting).• A third step in which the focusing of the beam is repeated for all spots (except 3 which has alreadybeen d<strong>on</strong>e in the previous step).13.3 LM-STEM Beam-shift pivot pointsPurpose: Align beam shift pivot point = make sure that the beam does not tilt when it is shifted in LM-STEM.Importance: ESSENTIAL for for keeping the beam parallel to the optical axis when shifting so that :• The STEM magnificati<strong>on</strong> calibrati<strong>on</strong> remains accurate.• The STEM image is not distorted.• The diffracti<strong>on</strong> pattern does not move off the detector during scanning.• The image is in focus from <strong>on</strong>e edge to the other.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!