11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 82<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2Notes:• The lowermost EFTEM-LM magnificati<strong>on</strong>s may not be usable. Simply skip the alignment for thesemagnificati<strong>on</strong>s.• Because of the difficulty of aligning the microscope for EFTEM (image/diffracti<strong>on</strong> shift and cross-overcorrecti<strong>on</strong> are often quite critical, otherwise there is no image or diffracti<strong>on</strong> pattern visible <strong>on</strong> theImaging Filter), the EFTEM alignment procedure c<strong>on</strong>tains two parts, <strong>on</strong>e a pre-alignment, where allalignments are d<strong>on</strong>e with the screen down, the other the final alignment where all is aligned <strong>on</strong> theFilter itself. Once the microscope has been aligned properly, the pre-alignment should not benecessary anymore and the final alignment can be used for fine-tuning.• In case the cross-over correcti<strong>on</strong> is str<strong>on</strong>gly misaligned, it is possible to switch to the cross-overcorrecti<strong>on</strong> adjustment and back by pressing the R2 butt<strong>on</strong>.15.5 LM-EFTEM Image-shift alignmentPurpose: Aligning all EFTEM-LM images with each other and with the LM images of the normal mode.Importance: CONVENIENCE so that the image remains centered when the magnificati<strong>on</strong> is changed.Method: Center a recognizable image with the specimen stage. Lower the magnificati<strong>on</strong> <strong>on</strong>e step,center the image with the Multifuncti<strong>on</strong> X,Y knobs. Repeat for all magnificati<strong>on</strong>s.ProcedureThe alignment procedure c<strong>on</strong>sists of four steps :• A preparati<strong>on</strong> step in which an image feature is centered (with the specimen stage) in the highest LMmagnificati<strong>on</strong> for the normal mode.• A step in which the same feature is centered with the MF-X,Y for the highest EFTEM-LMmagnificati<strong>on</strong>.• A step in which all EFTEM-LM magnificati<strong>on</strong>s are aligned relative to the highest EFTEM-LMmagnificati<strong>on</strong>.• A step in which the cross-over correcti<strong>on</strong> is set for each EFTEM-LM magnificati<strong>on</strong>.Notes:• The lowermost EFTEM-LM magnificati<strong>on</strong>s may not be usable. Simply skip the alignment for thesemagnificati<strong>on</strong>s.• Because of the difficulty of aligning the microscope for EFTEM (image/diffracti<strong>on</strong> shift and cross-overcorrecti<strong>on</strong> are often quite critical, otherwise there is no image or diffracti<strong>on</strong> pattern visible <strong>on</strong> theImaging Filter), the EFTEM alignment procedure c<strong>on</strong>tains two parts, <strong>on</strong>e a pre-alignment, where allalignments are d<strong>on</strong>e with the screen down, the other the final alignment where all is aligned <strong>on</strong> theFilter itself. Once the microscope has been aligned properly, the pre-alignment should not benecessary anymore and the final alignment can be used for fine-tuning.• In case the cross-over correcti<strong>on</strong> is str<strong>on</strong>gly misaligned, it is possible to switch to the cross-overcorrecti<strong>on</strong> adjustment and back by pressing the R2 butt<strong>on</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!