Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 47<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 29 Beam Nanoprobe procedure9.1 Preparati<strong>on</strong> Beam Nanoprobe alignmentPurpose: Set up microscope for aligning the upper part of the column (c<strong>on</strong>denser system) inNanoprobe.Importance: ESSENTIAL to make sure that the alignment is d<strong>on</strong>e for the correct c<strong>on</strong>diti<strong>on</strong>s: centeredC2 aperture, eucentric height and specimen in focus.Method:C2 aperture centering:• Focus spot and center it <strong>on</strong> the screen• Turn INTENSITY overfocus (clockwise)• Center aperture until illuminated area is symmetrical around the screen centerEucentric height: with the CompuStage switch <strong>on</strong> the Alpha wobbler and minimize image movement bychanging the Z height.9.2 Pivot point beam shift NanoprobePurpose: Align beam shift pivot point = make sure that the beam does not tilt when it is shifted.Importance: ESSENTIAL for keeping the beam parallel to the optical axis when shifting.Method: Shifting a beam parallel to itself means that it must always go through the fr<strong>on</strong>t-focal point (=shift pivot point) of the objective lens. This plane is c<strong>on</strong>jugate to the back-focal (diffracti<strong>on</strong>) plane and thealignment of the pivot point can thus be seen in diffracti<strong>on</strong>. The shift 'wobble' d<strong>on</strong>e by the microscopeshould give no beam tilt, so the two central spots in the diffracti<strong>on</strong> pattern should overlap.ProcedureThe alignment procedure c<strong>on</strong>sists of four steps:• Two preparati<strong>on</strong> steps for setting up the image and diffracti<strong>on</strong> pattern, respectively.• Two steps in which the X and Y pivot points are aligned.Notes:• The shift 'wobble' may have <strong>on</strong>e beam positi<strong>on</strong> blocked by the specimen. If no sec<strong>on</strong>d beam isvisible when turning MF-X, then (re)move the specimen.• Diffracti<strong>on</strong> focus: the Intensity setting is preset to a fixed value that should give a (nearly) parallelincident beam which in turn should give a spot diffracti<strong>on</strong> pattern. In order to keep the diffracti<strong>on</strong>focus the same as in the microprobe mode (where it can be set more reliably), the pattern should befocused (after it has been focused properly in microprobe) with the Intensity, not Focus.9.3 Pivot point beam tilt NanoprobePurpose: Align beam tilt pivot point = make sure that the beam does not shift when it is tilted.Importance: ESSENTIAL for keeping the beam centered during rotati<strong>on</strong> center alignment, focusing withthe wobbler and dark-field operati<strong>on</strong>.Method: A tilting beam must remain centered <strong>on</strong> the specimen (so the tilt pivot point coincides with thespecimen). The tilt wobble d<strong>on</strong>e by the microscope should give no beam shift, so <strong>on</strong>ly <strong>on</strong>e spot shouldbe visible in the image.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!