11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 45<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 28.8 Beam shift - image shift calibrati<strong>on</strong> LMPurpose: Define the beam shift compensati<strong>on</strong> for the image shift.Importance: CONVENIENCE for keeping the beam <strong>on</strong> the screen when the image is shifted. The beamshift - image shift is used in the Image shift C<strong>on</strong>trol Panel and in Low Dose.Method: Move the image off-axis and recenter the beam using Multifuncti<strong>on</strong> X,Y.Note: This procedure is complicated by the fact that it is not easy to tell how far the beam-shift/imageshiftshould be changed. The <strong>on</strong>-<strong>line</strong> <strong>help</strong> file therefore c<strong>on</strong>tains a c<strong>on</strong>trol that indicates the status of thebeam-shift/image-shift, beam coils and image coils.Using this you change the beam shift-image shift until either:• the beam is at the screen edge.• the beam shift-image shift is more than 50% (barbecomes green) OR <strong>on</strong>e of the coils is more than 80%(bar becomes red).The microscope will sound a beep when the beam shift-imageshift is at its limit but also when <strong>on</strong>e of the coils is at its limit.In the former case you can c<strong>on</strong>tinue with the calibrati<strong>on</strong>, butwhen a coil is limited very likely you cannot. The c<strong>on</strong>trol in the<strong>help</strong> file which is directly linked to the microscope displays thesituati<strong>on</strong>.ProcedureThe calibrati<strong>on</strong> procedure c<strong>on</strong>sists of six steps:• In the first step the beam is shifted to the center of the screen. For this purpose the alignment valueis used while the user value is reset to zero. At the same time the image shift is set to zero.• In the sec<strong>on</strong>d step, the image shift X is changed, either until the microscope beeps (at the limit of theimage shift) or until the beam moves off the screen (the latter typically happens when the calibrati<strong>on</strong>has not been d<strong>on</strong>e yet).• In the third step the beam is recentered using the Multifuncti<strong>on</strong> X,Y. If the microscope beeped duringthe sec<strong>on</strong>d step, c<strong>on</strong>tinue, otherwise step back and repeat the sec<strong>on</strong>d and third steps (so the finalcalibrati<strong>on</strong> is d<strong>on</strong>e with the image shift at its limit).• The fourth and fifth steps repeat the same procedure as the sec<strong>on</strong>d and third steps, but this time forthe Y image shift.• The final step just ensures that the image-beam shift is reset to zero after the procedure is finished.Descripti<strong>on</strong>The <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> microscope has a functi<strong>on</strong> for image shift where the beam positi<strong>on</strong> is automaticallycompensated to keep the beam <strong>on</strong> the area of interest (what is currently seen <strong>on</strong> the viewing screen).The beam shift compensati<strong>on</strong> must be calibrated before it will work properly.For a schematic diagram of the beam shift-image shift, see secti<strong>on</strong> 6.16.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!