11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 41<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 28 Image LM Procedure8.1 Preparati<strong>on</strong> Image LM alignmentPurpose: Set up microscope for aligning the lower part of the column (imaging system) in LM.Importance: ESSENTIAL to make sure that the alignment is d<strong>on</strong>e for the correct c<strong>on</strong>diti<strong>on</strong>s: centeredC2 aperture, eucentric height and specimen in focus.Method:C2 aperture centering:• Focus spot and center it <strong>on</strong> the screen• Turn INTENSITY overfocus (clockwise)• Center aperture until illuminated area is symmetrical around the screen centerEucentric height: with the CompuStage switch <strong>on</strong> the Alpha wobbler and minimize image movement bychanging the Z height.8.2 Pivot point image shift LMPurpose: Align image shift pivot point = make sure that the LAD diffracti<strong>on</strong> pattern does not shift whenthe image shift is changed.Importance: ESSENTIAL for the proper functi<strong>on</strong>ing of image shifts.Method: Minimize the movement of the diffracti<strong>on</strong> pattern. The microscope 'wobbles' the image shiftwhich should cause no diffracti<strong>on</strong> shift.ProcedureThe alignment procedure c<strong>on</strong>sists of four steps:• Two preparati<strong>on</strong> steps for setting up the image and diffracti<strong>on</strong> pattern, respectively.• Two steps in which the X and Y pivot points are aligned.Note: Diffracti<strong>on</strong> focus: in LAD the objective lens (which is here the focusing lens) is switched to fixedsetting. To focus the diffracti<strong>on</strong> pattern to a spot pattern the Intensity should be used, not the Focus.Only if the pattern cannot be focused with the Intensity should the Focus knob (objective lens) be used.In the latter case, turn the Intensity completely overfocus (clockwise), then focus the LAD pattern withthe Focus knob.Descripti<strong>on</strong>The alignment of the pivot points of the image deflecti<strong>on</strong> coils is essential to the proper functi<strong>on</strong>ing ofmany other alignments and calibrati<strong>on</strong>s: image shifts, diffracti<strong>on</strong> shifts, detector alignments andmeasurement functi<strong>on</strong>s.The image coils pivot points (image shift and diffracti<strong>on</strong> shift) alignment is reas<strong>on</strong>ably insensitive to theoperating c<strong>on</strong>diti<strong>on</strong>s and normally needs to be d<strong>on</strong>e <strong>on</strong>ly <strong>on</strong>ce. It is important that the image coils pivotpoints are aligned prior to aligning other parts of the microscope where the image coils are used,otherwise the latter alignments may have to be red<strong>on</strong>e. <strong>Alignments</strong> where the image coils are used arethose where images or diffracti<strong>on</strong> patterns are moved (image shift, diffracti<strong>on</strong> shift/diffracti<strong>on</strong> alignment).8.3 Pivot point diffracti<strong>on</strong> shift LMPurpose: Align the diffracti<strong>on</strong> shift pivot point = make sure the image does not move when the diffracti<strong>on</strong>shift is changed.Importance: ESSENTIAL for the proper functi<strong>on</strong>ing of image and diffracti<strong>on</strong> shifts.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!