11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 77<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 214.14 HM-EFTEM Mi Image shiftPurpose: Aligning the EFTEM Mi magnificati<strong>on</strong> images with SA and finding the difference in focus.Importance: CONVENIENCE so that the image remains centered when the magnificati<strong>on</strong> is changed.Method: Center a recognizable image with the specimen stage. Lower the magnificati<strong>on</strong> <strong>on</strong>e step,center the image with the Multifuncti<strong>on</strong> X,Y knobs. Repeat for all magnificati<strong>on</strong>s.ProcedureThe alignment procedure c<strong>on</strong>sists of three steps :• A preparati<strong>on</strong> step in which an image feature is centered (with the specimen stage) at the lowermostEFTEM-SA magnificati<strong>on</strong>.• A step in which the highest EFTEM-Mi magnificati<strong>on</strong> is aligned relative to the lowermost EFTEM-SAmagnificati<strong>on</strong>.• A step in which all EFTEM-Mi magnificati<strong>on</strong>s are aligned to the lowermost EFTEM-SA magnificati<strong>on</strong>.Notes:• Because of the difficulty of aligning the microscope for EFTEM (image/diffracti<strong>on</strong> shift and cross-overcorrecti<strong>on</strong> are often quite critical, otherwise there is no image or diffracti<strong>on</strong> pattern visible <strong>on</strong> theImaging Filter), the EFTEM alignment procedure c<strong>on</strong>tains two parts, <strong>on</strong>e a pre-alignment, where allalignments are d<strong>on</strong>e with the screen down, the other the final alignment where all is aligned <strong>on</strong> theFilter itself. Once the microscope has been aligned properly, the pre-alignment should not benecessary anymore and the final alignment can be used for fine-tuning.• In case the cross-over correcti<strong>on</strong> is str<strong>on</strong>gly misaligned, it is possible to switch to the cross-overcorrecti<strong>on</strong> adjustment and back by pressing the R2 butt<strong>on</strong>.14.15 HM-EFTEM Mi Cross-over correcti<strong>on</strong>Purpose: Make sure the cross-over correcti<strong>on</strong> is set correctly, so the beam passes unhindered throughthe differential pumping aperture.Importance: ESSENTIAL for having the image visible <strong>on</strong> the Imaging Filter, especially at the lowermagnificati<strong>on</strong>s.Method: Change the cross-over correcti<strong>on</strong> until there is no shadowing by the differential pumpingaperture. For best results, change the cross-over correcti<strong>on</strong> first <strong>on</strong> Multifuncti<strong>on</strong>-X in <strong>on</strong>e directi<strong>on</strong> untila shadow appears. Turn the other way while 'counting' turns until the shadow <strong>on</strong> the other side appears.Turn back halfway. Repeat for Multifuncti<strong>on</strong> Y.ProcedureThe alignment procedure c<strong>on</strong>sists of two steps :• A preparati<strong>on</strong> step in the lowest EFTEM-SA magnificati<strong>on</strong>.• A step in which the cross-over correcti<strong>on</strong>s are set for all EFTEM-Mi magnificati<strong>on</strong>s.Notes:• Because of the difficulty of aligning the microscope for EFTEM (image/diffracti<strong>on</strong> shift and cross-overcorrecti<strong>on</strong> are often quite critical, otherwise there is no image or diffracti<strong>on</strong> pattern visible <strong>on</strong> theImaging Filter), the EFTEM alignment procedure c<strong>on</strong>tains two parts, <strong>on</strong>e a pre-alignment, where allalignments are d<strong>on</strong>e with the screen down, the other the final alignment where all is aligned <strong>on</strong> theFilter itself. Once the microscope has been aligned properly, the pre-alignment should not benecessary anymore and the final alignment can be used for fine-tuning.• In case the image shift is str<strong>on</strong>gly misaligned, it is possible to switch to the image shift adjustmentand back by pressing the R2 butt<strong>on</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!