11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 72<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2ProcedureThe alignment procedure c<strong>on</strong>sists of three steps :• A preparati<strong>on</strong> step for setting up the image in EFTEM mode.• Two steps in which the X and Y pivot points are aligned.The preparati<strong>on</strong> here does not c<strong>on</strong>tain a step for the normal mode, because it is assumed that that hasalready been d<strong>on</strong>e for the SA pivot points.Descripti<strong>on</strong>The alignment of the pivot points of the image deflecti<strong>on</strong> coils is essential to the proper functi<strong>on</strong>ing ofmany other alignments and calibrati<strong>on</strong>s: image shifts, diffracti<strong>on</strong> shifts, detector alignments andmeasurement functi<strong>on</strong>s.The image coils pivot points (image shift and diffracti<strong>on</strong> shift) alignment is reas<strong>on</strong>ably insensitive to theoperating c<strong>on</strong>diti<strong>on</strong>s and normally needs to be d<strong>on</strong>e <strong>on</strong>ly <strong>on</strong>ce. It is important that the image coils pivotpoints are aligned prior to aligning other parts of the microscope where the image coils are used,otherwise the latter alignments may have to be red<strong>on</strong>e. <strong>Alignments</strong> where the image coils are used arethose where images or diffracti<strong>on</strong> patterns are moved (image shift, diffracti<strong>on</strong> shift/diffracti<strong>on</strong> alignment).For images displaying the effect of the alignment, see secti<strong>on</strong> 6.3.14.5 HM-EFTEM Mi Diffracti<strong>on</strong>-shift pivot pointsPurpose: Align the diffracti<strong>on</strong> shift pivot point = make sure the image does not move when the diffracti<strong>on</strong>shift is changed.Importance: ESSENTIAL for the proper functi<strong>on</strong>ing of image and diffracti<strong>on</strong> shifts and the cross-overcorrecti<strong>on</strong>.Method: Minimize the movement of the image. The microscope 'wobbles' the diffracti<strong>on</strong> shift whichshould cause no image shift.A comm<strong>on</strong> c<strong>on</strong>sequence of a diffracti<strong>on</strong> shift that has not been aligned is a mismatch between the imagedetail selected with the selected area aperture and the area actually c<strong>on</strong>tributing to the diffracti<strong>on</strong>pattern. When the image coils have not been aligned properly, image and diffracti<strong>on</strong> shift are notuncoupled and the diffracti<strong>on</strong> shift will also cause an image shift, thereby moving the image detail out ofthe selected area aperture. In EFTEM a misaligned diffracti<strong>on</strong> shift will lead to an apparent image shiftwhen the cross-over correcti<strong>on</strong> is changed.ProcedureThe alignment procedure c<strong>on</strong>sists of three steps :• A preparati<strong>on</strong> step for setting up the image in EFTEM mode.• Two steps in which the X and Y pivot points are aligned.The preparati<strong>on</strong> here does not c<strong>on</strong>tain a step for the normal mode, because it is assumed that that hasalready been d<strong>on</strong>e for the SA pivot points.Descripti<strong>on</strong>The alignment of the pivot points of the image deflecti<strong>on</strong> coils is essential to the proper functi<strong>on</strong>ing ofmany other alignments and calibrati<strong>on</strong>s: image shifts, diffracti<strong>on</strong> shifts, detector alignments andmeasurement functi<strong>on</strong>s.The image coils pivot points (image shift and diffracti<strong>on</strong> shift) alignment is reas<strong>on</strong>ably insensitive to theoperating c<strong>on</strong>diti<strong>on</strong>s and normally needs to be d<strong>on</strong>e <strong>on</strong>ly <strong>on</strong>ce. It is important that the image coils pivotpoints are aligned prior to aligning other parts of the microscope where the image coils are used,otherwise the latter alignments may have to be red<strong>on</strong>e. <strong>Alignments</strong> where the image coils are used arethose where images or diffracti<strong>on</strong> patterns are moved (image shift, diffracti<strong>on</strong> shift/diffracti<strong>on</strong> alignment).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!