11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 35<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2ProcedureThe calibrati<strong>on</strong> procedure c<strong>on</strong>sists of six steps:• In the first step the beam is shifted to the center of the screen. For this purpose the alignment valueis used while the user value is reset to zero. At the same time the image shift is set to zero.• In the sec<strong>on</strong>d step, the image shift X is changed, either until the microscope beeps (at the limit of theimage shift) or until the beam moves off the screen (the latter typically happens when the calibrati<strong>on</strong>has not been d<strong>on</strong>e yet).• In the third step the beam is recentered using the Multifuncti<strong>on</strong> X,Y. If the microscope beeped duringthe sec<strong>on</strong>d step, c<strong>on</strong>tinue, otherwise step back and repeat the sec<strong>on</strong>d and third steps (so the finalcalibrati<strong>on</strong> is d<strong>on</strong>e with the image shift at its limit).• The fourth and fifth steps repeat the same procedure as the sec<strong>on</strong>d and third steps, but this time forthe Y image shift.• The final step just ensures that the image-beam shift is reset to zero after the procedure is finished.Descripti<strong>on</strong>The <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> microscope has a functi<strong>on</strong> for image shift where the beam positi<strong>on</strong> is automaticallycompensated to keep the beam <strong>on</strong> the area of interest (what is currently seen <strong>on</strong> the viewing screen).The beam shift compensati<strong>on</strong> must be calibrated before it will work properly.When the user shifts the image (from the centralgreen ray path to the off-axis, tan ray path), themicroscope automatically applies acompensating beam shift.6.17 Off-axis TV HM image alignment (<strong>on</strong>ly if off-axis TV installed)Purpose: Aligning all Mh and SA (as far as attainable) magnificati<strong>on</strong>s <strong>on</strong> the off-axis TV.Importance: CONVENIENCE so that the image is shifted automatically from the center of the viewingscreen to the off-axis TV camera .Method: Center a recognizable image <strong>on</strong> the viewing screen with the specimen stage. Center the imagewith the Multifuncti<strong>on</strong> X,Y knobs <strong>on</strong> the off-axis TV camera. Repeat for all attainable magnificati<strong>on</strong>s.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!