Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 54<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 211 Stigmator Procedure11.1 C<strong>on</strong>denser stigmator calibrati<strong>on</strong>The microscope c<strong>on</strong>tains a c<strong>on</strong>denser stigmator to correct for beam astigmatism. When this stigmator ismisaligned, adjustment of the stigmator setting will lead to an apparent beam shift. When the stigmator isaligned correctly, these shifts are compensated by an identical but opposite beam shift - this time usingthe beam deflecti<strong>on</strong> coils. In order to align the stigmator, it is necessary to determine the relati<strong>on</strong>between a change in stigmator setting and the beam shift. This relati<strong>on</strong> is determined in the procedurefor aligning the stigmator.The procedure follows these steps:• A preparati<strong>on</strong> step in which the beam is nearly (not completely) focused.• The current through the stigmator is wobbled in the X directi<strong>on</strong> and the operator minimizes beammovement.• The same is d<strong>on</strong>e for the Y directi<strong>on</strong>.• Two highly astigmatic beams (almost <strong>line</strong>s) should become visible. If the beams do not look like that,change the INTENSITY until they do. With the c<strong>on</strong>denser stigmator misaligned the two <strong>line</strong>s will notcross each other in the middle. Adjust the Multifuncti<strong>on</strong> knobs until they do.C<strong>on</strong>denser stigmator misaligned.C<strong>on</strong>denser stigmator aligned.11.2 Objective stigmator calibrati<strong>on</strong>The microscope c<strong>on</strong>tains an objective stigmator to correct for astigmatism in HM image and LMdiffracti<strong>on</strong>. When this stigmator is misaligned, adjustment of the stigmator setting will lead to an apparentHM image (or LM diffracti<strong>on</strong> shift). When the stigmator is aligned correctly, these shifts are compensatedby an identical but opposite shift - this time using the image deflecti<strong>on</strong> coils. In order to align thestigmator, it is necessary to determine the relati<strong>on</strong> between a change in stigmator setting and the HMimage shift. This relati<strong>on</strong> is determined in the procedure for aligning the stigmator.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!