11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 28<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2A comm<strong>on</strong> c<strong>on</strong>sequence of a diffracti<strong>on</strong> shift that has not been aligned is a mismatch between the imagedetail selected with the selected area aperture and the area actually c<strong>on</strong>tributing to the diffracti<strong>on</strong>pattern. When the image coils have not been aligned properly, image and diffracti<strong>on</strong> shift are notuncoupled and the diffracti<strong>on</strong> shift will also cause an image shift, thereby moving the image detail out ofthe selected area aperture.ProcedureThe alignment procedure c<strong>on</strong>sists of three steps:• A preparati<strong>on</strong> step for setting up the image.• Two steps in which the X and Y pivot points are aligned.Descripti<strong>on</strong>The alignment of the pivot points of the image deflecti<strong>on</strong> coils is essential to the proper functi<strong>on</strong>ing ofmany other alignments and calibrati<strong>on</strong>s: image shifts, diffracti<strong>on</strong> shifts, detector alignments andmeasurement functi<strong>on</strong>s.The image coils pivot points (image shift and diffracti<strong>on</strong> shift) alignment is reas<strong>on</strong>ably insensitive to theoperating c<strong>on</strong>diti<strong>on</strong>s and normally needs to be d<strong>on</strong>e <strong>on</strong>ly <strong>on</strong>ce. It is important that the image coils pivotpoints are aligned prior to aligning other parts of the microscope where the image coils are used,otherwise the latter alignments may have to be red<strong>on</strong>e. <strong>Alignments</strong> where the image coils are used arethose where images or diffracti<strong>on</strong> patterns are moved (image shift, diffracti<strong>on</strong> shift/diffracti<strong>on</strong> alignment).Misaligned diffracti<strong>on</strong> shift pivot point.Aligned diffracti<strong>on</strong> shift pivot point.6.4 Objective Lens preset SAPurpose: Setting the eucentric focus preset at the eucentric height.Importance: CONVENIENCE for having the eucentric focus at the eucentric height.Method: Focus the image for the highest SA magnificati<strong>on</strong>.Procedure• The alignment procedure c<strong>on</strong>sists of two steps:• A preparati<strong>on</strong> step in which the SA image is focused at an intermediate magnificati<strong>on</strong>.• A step in which the highest SA magnificati<strong>on</strong> must be focused.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!