11.07.2015 Views

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

Tecnai on-line help manual -- Alignments - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> <strong>Alignments</strong> 55<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12 Software versi<strong>on</strong> 2The procedure follows these steps:• A preparati<strong>on</strong> step in which the HM image is focused.• The current through the stigmator is wobbled in the X directi<strong>on</strong> and the operator minimizes imagemovement.• The same is d<strong>on</strong>e for the Y directi<strong>on</strong>.The stigmator current wobble will result in two images, which will overlap when the stigmators arealigned correctly. It is advisable to use a specimen with relatively large, easily recognized image detail.Misaligned objective stigmator.Aligned objective stigmator.11.3 Diffracti<strong>on</strong> stigmator calibrati<strong>on</strong>The microscope c<strong>on</strong>tains a diffracti<strong>on</strong> stigmator to correct for astigmatism in HM diffracti<strong>on</strong> and LMimage. When this stigmator is misaligned, adjustment of the stigmator setting will lead to an apparentHM diffracti<strong>on</strong> shift / LM image shift. When the stigmator is aligned correctly, these shifts arecompensated by an identical but opposite shift - this time using the image deflecti<strong>on</strong> coils. In order toalign the stigmator, it is necessary to determine the relati<strong>on</strong> between a change in stigmator setting andthe LM image shift. This relati<strong>on</strong> is determined in the procedure for aligning the stigmator.The procedure follows these steps:• A preparati<strong>on</strong> step in which the microscope is switched to LM and the image is focused.• The current through the stigmator is wobbled in the X directi<strong>on</strong> and the operator minimizes imagemovement.• The same is d<strong>on</strong>e for the Y directi<strong>on</strong>.The stigmator current wobble will result in two images, which will overlap when the stigmators arealigned correctly. It is advisable to use a specimen with relatively large, easily recognized image detail.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!