12.07.2015 Views

Douglas County Rules and Regulations for Swimming Pools - Cobb ...

Douglas County Rules and Regulations for Swimming Pools - Cobb ...

Douglas County Rules and Regulations for Swimming Pools - Cobb ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

c.) Equipment clearance. A ll equipment <strong>and</strong> piping shall be installed to facilitate servicingwith minimal ef<strong>for</strong>t. Filter tanks shall be at least eight inches (8”) apart, twelve inches (12”)from walls, <strong>and</strong> thirty-six inches (36”) from the ceiling. Ceiling height shall be a minimum ofeight f eet (8’) from t he floor s urface. Clearance a round a ll e quipment <strong>and</strong> a ppurtenancesmust permit unobstructed, ready access <strong>for</strong> inspection, maintenance, <strong>and</strong> operation.d.) Electrical controls. No s witches, s tarters, pa nel boa rds or s imilar electrical equi pmentshall be located in areas accessible to bathers, except <strong>for</strong> therapy or booster pump jet or inlettimers <strong>and</strong> emergency shut-off switches that must be properly grounded.Part 20 Diving Areas <strong>and</strong> Equipmenta.) Dimensions. Dimensions ( width, de pth <strong>and</strong> l ength) of t he di ving a rea s hall be i naccordance with anticipated use by divers, <strong>and</strong> with the applicable sanctioning organizationrecognized <strong>and</strong> approved by t he de partment. The di mensions s hall c omply with t herequirements as stipulated in the Appendix, Figures #1 & #2.b.) Clearance. Diving boards or diving plat<strong>for</strong>ms must be installed no less than ten feet (10’)apart (edge to edge) <strong>and</strong> no less than ten feet (10’) from any pool side wall, or in accordancewith the manufacturer’s specifications, whichever is the greater distance. At least fifteen feet(15’) o f f ree, unobs tructed c learance s hall be provided a bove di ving boards a nd di vingplat<strong>for</strong>ms.c.) Finish <strong>and</strong> Use. D iving boa rds a nd pl at<strong>for</strong>ms s hall ha ve a l ight c olored, slip-resistantfinish. Starting plat<strong>for</strong>ms shall be used only <strong>for</strong> competitive swimming, shall have a lightcolored,slip-resistant finish, <strong>and</strong> shall be removed from the deck when not being used <strong>for</strong>their intended purpose.d.) Safety. Approved diving equipment shall be installed only on pool types that are equal toor l arger t han t he pool t ype de signated b y t he manufacturer. D iving e quipment s hall beinstalled according to the manufacturer’s instructions <strong>and</strong> specifications <strong>and</strong> this article. Alldiving st<strong>and</strong>s higher than twenty-one inches (21”) measured from the deck to the top of thesecured end of the board shall be provided with stairs <strong>and</strong>/or a ladder. Steps <strong>and</strong> ladders shallbe of corrosion-resistant material, easily cleanable <strong>and</strong> with treads that are slip-resistant <strong>and</strong>self-draining. P lat<strong>for</strong>ms a nd di ving e quipment of one m eter (1m) s hall be pr otected w ithh<strong>and</strong>rails that shall be at least thirty inches (30”) above the diving board or plat<strong>for</strong>m surface.All plat<strong>for</strong>ms or diving equipment higher than one meter (1m) shall have dual h<strong>and</strong>rails thatare approximately eighteen inches (18”) from the bottom rail <strong>and</strong> thirty-six inches (36”) fromthe top rail above the diving board or plat<strong>for</strong>m surface. A ll plat<strong>for</strong>m or diving equipmentgreater than one meter (1m) in height shall have dual h<strong>and</strong>rails installed at a maximum of onemeter ( 1m) a bove t he deck l evel a nd c ontinuous a bove t he boa rd or pl at<strong>for</strong>m, a nd i naccordance w ith manufacturer’s s pecifications. All r equired h<strong>and</strong>rails f or di vingplat<strong>for</strong>ms/boards shall e xtend over to at least the edge of the pool wall. Diving equipmentshall be permanently anchored to the pool deck. A sign stating “Only one user allowed ondiving boa rd, plat<strong>for</strong>m or l adder at an y t ime” s hall be pos ted at t he ba se of a ccess t o t he<strong>Cobb</strong> <strong>and</strong> <strong>Douglas</strong> <strong>County</strong> Public Health<strong>Douglas</strong> <strong>Rules</strong> <strong>and</strong> Regs <strong>for</strong> <strong>Swimming</strong> <strong>Pools</strong>30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!