FOR MODELS: JG AND JGA SECTION 1 - DESIGN SPECIFICATIONS & DATA<br />

Optional Main Bearing Temperature Instrumentation -<br />

Alarm & Shutdown<br />

Eutectic Temperature Valve<br />

This eutectic alloy device is selected to melt at 228°F (109°C) to vent control pressure and<br />

to provide a shutdown signal. Upon melting, the fuse rod must be replaced. To ensure<br />

proper operation of the detector, replace the fuse rod every five years.<br />

Electrical Instrumentation Setting<br />

Set within 10% of normal operating temperature, to a maximum of 220°F (104°C) alarm and<br />

230°F (110°C) shutdown.<br />