FOR MODELS: JG AND JGA SECTION 3 - START UP<br />
Compressor Model ______________________ Serial No. F-______________________<br />
YES NO<br />
12. Have piston end clearances been checked with feeler gauges? _____ _____<br />
Record below:<br />
Throw #1 #2 #3 #4 #5 #6<br />
HE_______ _______ _______ _______ _______ _______<br />
CE_______ _______ _______ _______ _______ _______<br />
13. Has the crankcase been filled with oil to the proper level? _____ ______<br />
14. Has proper oil been installed if extreme ambient conditions<br />
exist or special gases are compressed? _____ ______<br />
15. Is the compressor crankcase oil level control working and<br />
set at the proper level? _____ ______<br />
16. Is the crankcase oil supply isolation valve open? _____ ______<br />
17. Does the crankcase low level shutdown work? _____ ______<br />
18. Have the recommended oil filter elements been installed? _____ ______<br />
19. Are the oil filter element and all lube oil piping primed with oil? _____ ______<br />
20. Is the low oil pressure shutdown installed and tubed correctly<br />
to the downstream side of the oil filter? _____ ______<br />
21. Does the low oil pressure shutdown work? _____ ______<br />
22. Oil cooler? Compressor inlet oil temperature is 190°F (88°C) max. _____ ______<br />
23. Is the crankcase oil temperature shutdown installed, set<br />
and working? _____ ______<br />
24. If oil is cooled, is there a temperature control valve? _____ ______<br />
25. Is the crankcase breather element clean? _____ ______<br />
26. Is the force feed lubricator box filled with proper oil? _____ ______<br />
27. Is the force feed lubrication system primed/purged? _____ ______<br />
28. Is the force feed lubrication system no flow shutdown<br />
installed and working? _____ ______<br />
29. Is the force feed blow out assembly installed? Check rupture<br />
disc for color? Purple is standard = 3250 PSIG (22 400 kPa). _____ ______<br />
30. Has the lubricator instruction plate or “Parts Book” Cylinder<br />
Lubrication Sheet been checked for proper lube feed rate? _____ ______<br />
31. Is there a working vibration shutdown mounted on compressor? _____ ______<br />
32. Are the primary and secondary packing vents and the distance<br />
piece vents open, and when necessary, tubed off of the skid or<br />
out of the building? _____ ______<br />
33. Is there some method of suction pressure control? _____ ______<br />
34. Are the suction pressure, interstage pressure and discharge<br />
pressure shutdowns set and working? _____ ______<br />
35. Are the safety relief valves installed and working to protect<br />
cylinders and piping for each stage of compression? _____ ______<br />
11/01 PAGE 3 - 3