FOR MODELS: JG AND JGA SECTION 3 - START UP<br />

Relief Valve Settings<br />

It is the responsibility of the packager to provide relief valves for every stage of compression<br />

in compliance with API SPEC 11P, paragraph 7.20.3, as follows:<br />

"Relief valve setting shall take into consideration all possible types of equipment<br />

failure and the protection of the lowest pressure rated component in any continuous<br />

system. Relief valves shall be set to operate at not more than the maximum<br />

allowable working pressures but not less than the values following:<br />

System Discharge Relief Valve Margin<br />

Pressure Above System<br />

psig (kPa) Discharge Pressure<br />

-14.7 to 150 (-101 to 1034) 15 PSI (100 kPa)<br />

151 to 2500 (1035 to 17 237) 10%<br />

2501 to 3500 (17 238 to 24 132) 8%<br />

3501 to 5000 (24 133 to 34 474) 6%<br />

NOTE: For rated discharge pressures above 5000 psig (34 474 kPa), the relief<br />

valve setting shall be agreed upon between the purchaser and the vendor.”<br />

!<br />

CAUTION<br />

WHEN A BYPASS IS FURNISHED, A RELIEF VALVE MUST<br />

BE INSTALLED IMMEDIATELY DOWNSTREAM OF THE<br />

BYPASS VALVE OR ON THE INLET SCRUBBER OF THE<br />

DOWNSTREAM CYLINDER. THIS RELIEF VALVE MUST BE<br />

SET FOR THE MAXIMUM ALLOWABLE WORKING PRES-<br />

SURE OF THE CYLINDER WHICH HAS THE LOWEST MAWP<br />

OF THOSE IN THE BYPASS CIRCUT. THIS IS TO PROTECT<br />

AGAINST DISCHARGE-CHECK VALVE FAILURE WHEN<br />

OPERATING ON BYPASS. (SEE ARIEL PACKAGER’S STAN-<br />

DARDS, SECTION 4.4 “RELIEF VALVES”).<br />