30.11.2012 Views

Heavy Duty Balanced Opposed Compressors

Heavy Duty Balanced Opposed Compressors

Heavy Duty Balanced Opposed Compressors

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FOR MODELS: JG AND JGA SECTION 4 - LUBRICATION AND VENTING<br />

2 Disconnect wiring and loosen set screws. Remove DNFT housing to a safe<br />

atmosphere.<br />

3 Use 3/8 inch ratchet wrench to remove the pipe plug.<br />

4 Remove battery from the DNFT and disconnect from the polarized connector.<br />

5 Connect the new battery (Ariel part number A-10807 or Radio Shack 960-0418)<br />

to the attached polarized plug.<br />

6 Reinsert the battery and reinstall pipe plug.<br />

7 Replace DNFT control housing on the magnet housing to original position and<br />

tighten set screws. Reattach wiring and conduit.<br />

8 Verify the DNFT is working by pre-lubing the system and check for LED blink<br />

See the Ariel web site - vendor literature - Whitlock for more details on DNFT’s.<br />

MAGNET<br />

HOUSING<br />

MAGNET<br />

O-RING<br />

CONTROL HOUSING<br />

HEAD<br />

ALLEN<br />

SCREWS(2)<br />

SET<br />

SPACER<br />

POLARIZED CONNECTOR<br />

FIGURE 4-5: DIGITAL NO-FLOW TIMER SWITCH - (DNFT)<br />

Assembly Instructions For Divider Valves<br />

LED<br />

NOTE: THE CENTER TIE ROD IN THE BASEPLATE IS OFFSET SO THAT THE INTER-<br />

MEDIATE BLOCKS CANNOT BE ASSEMBLED BACKWARDS. IF EXCESSIVE<br />

FORCE IS ENCOUNTERED DURING ASSEMBLY, MAKE SURE BLOCK IS NOT<br />

BACKWARDS.<br />

1. Screw three tie rods into inlet block until ends are flush with surface of block.<br />

2 Slide inlet gasket onto tie rods.<br />

3 Alternately slide an intermediate block and an intermediate gasket plate onto the<br />

tie rods until the last intermediate block is in place.<br />

4 Discard remaining intermediate gasket plate.<br />

5 Slide end gasket plate and end block onto tie rods.<br />

6 Lay baseplate assembly on flat surface and tightening nuts to 72 lb-in. (8.1<br />

N·m), torque.<br />

7 Mount divider valves with gasket plates onto baseplate and tightening mounting<br />

screws to 108 lb-in. (12.2 N·m), torque.<br />

PAGE 4 - 16 11/01<br />

SPRING<br />

REPLACEABLE<br />

FIELD<br />

BATTERY<br />

ARIEL P/N:A-10807<br />

#22 AWG 18" LEADS (7)<br />

RED<br />

RED<br />

ORANGE<br />

GREEN<br />

ORANGE<br />

YELLOW<br />

YELLOW<br />

1/2“ PIPE PLUG