12.07.2015 Views

surveying iii (topographic and geodetic surveys) - Modern Prepper

surveying iii (topographic and geodetic surveys) - Modern Prepper

surveying iii (topographic and geodetic surveys) - Modern Prepper

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

a. Unpacking <strong>and</strong> Performing Instrument Setup.(1) Erect the tripod over the station point, hang the plumb line by the hook on the central fixingscrew, <strong>and</strong> center the tripod to 1 or 2 centimeters. For instrument stability, tread the feet of the tripodfirmly into the ground. For precise measurements, see that both the tripod <strong>and</strong> the instrument arecompletely protected from the direct rays of the sun.(2) Grasp the two ends of the leather strap of the instrument casing, <strong>and</strong> draw them forciblyoutward so that the two lever fastenings open <strong>and</strong> the hood can be cautiously lifted <strong>and</strong> removed.(3) Loosen the three black screws that hold the instrument to the bedplate of the casing <strong>and</strong> drawback the three slides. Lift the instrument using its two scope supports, <strong>and</strong> place it on the tripod in sucha way that the illuminating mirror for the horizontal circle (9) can be turned toward the light. Screw thecentral fixing screw of the tripod into the footplate of the instrument <strong>and</strong>, after centering the instrumentexactly over the point with the plumb line, tighten the fixing screw.(4) To set up the instrument on an observation pillar, set the cast-iron base plate on the pillar <strong>and</strong>accurately center it using a centering pin with a circular level. Place the instrument on the base plate <strong>and</strong>affix it by turning the central fixing screw with the provided pin.b. Instrument Leveling. Turn the upper part of the instrument into such a position that the platespirit level (15) between the telescope supports lies parallel to a line joining two of the foot screws (20).Turn the two foot screws simultaneously but in opposite directions until the bubble in the level iscentered. (The bubble sensitivity of the plate level is 5 to 7 seconds per 2-millimeter graduation.) Turnthe upper part of the instrument through 90° <strong>and</strong> again center the bubble by turning the third foot screw.Turn the instrument through 180°. If the plate spirit level is correctly adjusted, the bubble will come torest at the center. If the bubble is off center, move the bubble halfway back toward the center using theplate-level adjusting screw. Center the bubble in its vial by turning the foot screws. The resultingposition of the bubble is called the adjustment position. It corresponds to a vertical position of thevertical axis. Repeat this test, making any additional required adjustments of the plate spirit level. Theadjustment of the plate spirit level should be tested every time the theodolite is set up for use. It isessential that the plate spirit level be protected from the direct rays of the sun; otherwise, the position ofthe bubble will not remain stationary throughout a complete rotation.c. Focusing. Direct the telescope toward the sky or a light source. Without observing thebackground, turn the edged, black diopter ring on the telescope eyepiece (6) until the crosshairs appearsharp <strong>and</strong> black. Note the setting on the numbered scale. This will remain constant for one observer.To focus to obtain a clear image of a sighted object, turn the focusing ring for the telescope (3). Testyour absence of parallax between the crosshairs <strong>and</strong> the image by moving your eye3-17 EN0593

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!