12.07.2015 Views

12LS Controller Installation and Operation Manual, Rev 3 ... - Watlow

12LS Controller Installation and Operation Manual, Rev 3 ... - Watlow

12LS Controller Installation and Operation Manual, Rev 3 ... - Watlow

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Guided Menus Simplify SetupThe ANAFAZE <strong>12LS</strong> directs operator <strong>and</strong> supervisor changes with guided menus. Two levels areprovided: one for operator changes <strong>and</strong> one for supervisor controller setup.Operator Changes: Single dedicated keys are used to make process changes from thesingle loop display. The setpoint can be changed, the loop can be set to auto or manual,<strong>and</strong> ramp <strong>and</strong> soak loops can be started, held, or stopped. If the loop is set to manual, thepercent output can be changed. These changes can be locked out from the supervisormenus if desired.Supervisor Setup: Detailed editing is done by pressing a special sequence of keys to enterthe setup menus. The supervisor is guided through a list of functions to change:Global? This is used to save <strong>and</strong> restore jobs, define action on power up,communications address <strong>and</strong> baud rate, communications error checking, panel lock,<strong>and</strong> alarm delay.Inputs? Input sensor type, engineering units, scaling, <strong>and</strong> sample time for pulseinputs.Control? The loop control constants including: Proportional gain [P], Integral orreset [I], <strong>and</strong> derivative or rate [D], <strong>and</strong> a digital output filter. For the dual outputs,a second gain, reset, rate, filter <strong>and</strong> spread can be entered for the second output.Output? Selects the control output including: analog, on/off, cycle timeproportioning, distributed zero crossing, <strong>and</strong> reverse [heat] or direct [cool] action.The heat output can be directed to the terminals or ribbon connector.Alarms? Independent deviation alarm b<strong>and</strong>, high process, <strong>and</strong> low process alarmscan be set for each loop. Each alarm can be set to activate any of the digital outputson alarm. A deadb<strong>and</strong> can be entered for each loop.Ramp/Soak? If this option is installed up to eight, 20 segment ramp <strong>and</strong> soakprofiles can be defined.I/O Test? This is used to check the state of the digital inputs <strong>and</strong> outputs.1-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!