- Page 1 and 2: ANAFAZE 12LSInstallation And Operat
- Page 3 and 4: WARNINGANAFAZE HAS MADE EFFORTS TO
- Page 5: 4.4 OPERATIONAL MENUS..............
- Page 9 and 10: The ANAFAZE 12LS front panel provid
- Page 11 and 12: Digital Inputs and Outputs Expand V
- Page 13 and 14: 2.2 Control CapabilityNumber of Loo
- Page 15 and 16: 3.0 INSTALLATIONThere are some prec
- Page 17 and 18: 1/8th DIN HOUSING3-3
- Page 19 and 20: 4. Use Thermocouple Extension Wire
- Page 21 and 22: 3. Separate the 120 vac power leads
- Page 23 and 24: REMOTE TERMINAL BLOCK CONNECTIONSTh
- Page 25 and 26: 3.3.5 INPUT SCALINGThe ANAFAZE 12LS
- Page 27 and 28: WARNINGUse of the grounded T/C, mea
- Page 29 and 30: 3.4.1 PID CONTROL AND ALARM OUTPUTS
- Page 31 and 32: 3.5.3 RS-485 DESCRIPTIONThe EIA Sta
- Page 33 and 34: ANAFAZE 12LS connections for a sing
- Page 35 and 36: |- - - - - - - - - - - - - -|Back|-
- Page 37 and 38: 4.2 DISPLAYSOn power-up the control
- Page 39 and 40: |----------------------------------
- Page 41 and 42: 4.3 GENERAL PROGRAMMING AND EDITING
- Page 43 and 44: 4.4.2 SET LOOP TO MANUAL/AUTOTo tog
- Page 45 and 46: LOOP SETUP DATA|-------------------
- Page 47 and 48: The menu appears as:|--------------
- Page 49 and 50: 4.5.1.6 POWER UP OUTPUT STATUSThis
- Page 51 and 52: Press YES to select the menu or NO
- Page 53 and 54: The display appears as :|----------
- Page 55 and 56: The low input reading is referenced
- Page 57 and 58:
4.5.3.1 PROPORTIONAL BANDThe first
- Page 59 and 60:
|----------------------------------
- Page 61 and 62:
Press UP and DOWN to set the maximu
- Page 63 and 64:
4.5.5.4 DEVIATION BAND ALARMThis me
- Page 65 and 66:
Press ENTER to store the status or
- Page 67 and 68:
4.6 RAMP AND SOAK OPTIONThe ramp an
- Page 69 and 70:
+----------------------------------
- Page 71 and 72:
4.6.3 PROFILE STATUS DISPLAYWhether
- Page 73 and 74:
An example display follows:|-------
- Page 75 and 76:
|----------------------------------
- Page 77 and 78:
PROFILE SETUP GUIDE4-44
- Page 79 and 80:
UP/DOWNSelect a profile designator
- Page 81 and 82:
When any segment is out of toleranc
- Page 83 and 84:
4.7.6 EDIT EXTERNAL RESETFrom this
- Page 85 and 86:
YESChange current setpoint setting.
- Page 87 and 88:
4.7.13 EDIT SEGMENT TRIGGERSUse thi
- Page 89 and 90:
4.7.16 EDIT TRIGGER LATCH STATUSDis
- Page 91 and 92:
4.7.19 EDIT PROFILE CYCLESThis menu
- Page 93 and 94:
5.1.5 DISTRIBUTED ZERO CROSSINGDist
- Page 95 and 96:
There is no tuning step for the Out
- Page 97 and 98:
5.2.6 GENERAL PID CONSTANTS BY APPL
- Page 99 and 100:
7.0 TROUBLE SHOOTING INFORMATION7.1
- Page 101 and 102:
If ANASOFT runs then the next step
- Page 103 and 104:
Data Boundary ErrorThis Error Code
- Page 105 and 106:
The following examples show the out
- Page 107 and 108:
Cycle TimeDeviationAlarmThe time ba
- Page 110: