Chapter 5Maintenance and TroubleshootingMaintenanceThe following maintenance is recommended to ensure optimal performance.FrequencyYearlyWhen neededMaintenance Required• Check all parameters and test points.• Record data.• Make adjustments as needed.• Make sure all cables are mated properly.• Inspect cables for stress and chafing.• Make sure all retaining screws are tight.• Replace chassis air filter, if present. Depending on officeenvironment cleanliness and filtration, the chassis air filter mayrequire more frequent servicing.Carefully clean the module with a soft cloth that is dampened withmild detergent.Maintenance RecordIt may be helpful to establish a maintenance record or log for this equipment. Youmay want to record laser power level, laser temperature readings, laser bias current,or power supply voltages, as well as the filter change dates.Large variations in any of the parameters above should be investigated prior tofailure.84 78-4037880-01 Rev B