LCTECH / GPC PRODUCT LINE3Intensity5000025000124GEL PERMEATION COLUMNSGPC COLUMNS; FUNCTIONALITY THROUGH AND THROUGHThe LCTech GPC columns are designed for easy and selfexplana<strong>to</strong>ryhandling. Due <strong>to</strong> their robustness, they can be usedfor every-day analysis in labora<strong>to</strong>ries.The columns are available lled or unlled as well as indifferent lengths and lling heights. Suitable lling kits areprovided for easy relling.A patented xture is used for simple and clean relling ofBio-Beads for re-use.FEATURE HIGHLIGHTS• Leak Tightness Due To Sophisticated Construction With Only AFew Sealing Elements Only• Simple And Self-Explana<strong>to</strong>ry Construction• Robust Layout• Pressure Stable (Max 20 Bars)• No Cross-Contamination In Subsequent Runs EvenWith Demanding Samples• Chemically Inert• Exchangeable 10 mm PTFE Frits• Available Ready-To-Use & Easily Refillable• DFG S19-Compliance (D25)• Column Cleaning & Refill Can Be Done By Cus<strong>to</strong>mer00 5 10 15 20 25 30 35 40 45 50minMATERIALSFILTER FRITSSCREWEDFITTINGSPRESSURELCTech GPC Columns - Tested QualityQA CHROMATOGRAM OF A COLUMN GPC10011Ethylacetate/Cyclohexane 5.0 mL/minInjection Volume 5 mLUV Detection at 254 nm1. Corn Oil 25 g/L2. Di (2-Ethylhexyl) Phthalate 1 g/L3. Methoxychlor 0.2 g/L4. Perylene 0.02 g/LTo each fi lled LCTech GPC Column, a QA chroma<strong>to</strong>gramis attached, showing the perfect separation of the testcomponents.GEL PERMEATION COLUMNS SPECIFICATIONSGlass, PTFE, aluminum and acetal, solvent resistance ofall parts10 µm, PTFE, exchangeableUNF 1/4” - 28 (standard lab screw connection)Max 20 barsP/NDIMENSIONS(TL x OD x ID)*FILLED GPC COLUMNSBIO-BEADSS-X3 FILLINGBEDLENGTHSOLVENT** METHOD (e.g.)GPC10011 500 x 40 mm, 25 mm 50 g 320 mm EA/CY 1/1 DFG S19GPC30011 660 x 40 mm, 25 mm 70 g 450 mm EA/CY 1/1 Modified USEPA 3640 AGPC40011 425 x 40 mm, 20 mm 24 g 225 mm EA/CP 7/3 FSIS CLG-CHC3GPC50011 780 x 55 mm, 25 mm 70 g 540 mm DCUSEPA 3640 A,EPA Method 8270 C, 8141 BGPC90011 500 x 40 mm, 25 mm 35 g 200 mm DC/HX 1/1 USP Monographs: Lanolin* TL = Total Length, OD = Outer Diameter, ID = Inner Diameter** CY = Cyclohexane; CP = Cyclopentane; DC = Dichlorometane; EA = Ethyl Acetate; HX = Hexane,Mixing ratio on volume basisNOTE: To ensure we sell you the best possible column for y<strong>our</strong> needs,please contact us with any questions, or for a quotation.
LCTECH / GPC PRODUCT LINEGPC QUATTROCATALOG NO.DESCRIPTION11389GPC quattro, Standard version, 96 - 240 V AC, 50-60 Hz(without columns)11391 Software UPGRADE (indiviual programming of each channel/column)11392 Waste Level Sensor UPGRADE (three more waste sensors)11393 Data & Process Visualization on PC via VNCViewerGPC UNOCATALOG NO.1160111607DESCRIPTIONGPC Uno (with one GPC-line), 96 - 240 V AC, 50-60 Hz(without columns)Upgrade of GPC uno by one GPC-line, consists of pump,electronic devices & tubingGPC QUATTRO & UNO ACCESSORIESCATALOG NO.DESCRIPTION10071 Syringe, 1.0 mL (Needle has <strong>to</strong> be ordered addionally)10072 Syringe, 5.0 mL (Needle has <strong>to</strong> be ordered separately)10074 Syringe, 10.0 mL (Needle has <strong>to</strong> be ordered separately)10075 Needle/Probe for syringesGPC VARIO85CATALOG NO.DESCRIPTIONGel Permeation Chroma<strong>to</strong>graphy (GPC) System - type VARIO,11006 The basic includes preparative HPLC-pump; one sample loop 5 mL; 110 VAC, 50 Hz.Chroma<strong>to</strong>graphy column, Sample Rack, bottles for equipping the rack as well as waste bottles are quoted separately.Gel Permeation Chroma<strong>to</strong>graphy (GPC-system) - type VARIO-A,11007 basic unit includes analytical HPLC-pump; one sample loop 1 mL; 110 VAC, 50 Hz.Chroma<strong>to</strong>graphy column, Sample Rack, bottles for equipping the rack as well as waste bottles are quoted separately.10835 Upgrade GPC VARIO Upgrade-set for an additional column, valves, tubes. This enables sample separation on different columns depending on the matrix.10879 Upgrade GPC Vario for High-Pressure VersionVarioSoft - PC-Software <strong>to</strong> control GPC Vario.10273PC-Requirements: Windows 98SE or higher; 2 GB Hard Drive; one RS232 Interface (Com-Port); CD Rom. Computer sold separately.GPC ULTRACATALOG NO.DESCRIPTIONFully Au<strong>to</strong>mated Sample Preparation System GPC ULTRA; Final volume 5 mL11201The combined GPC-Evapora<strong>to</strong>r-System performs the complete sample preparation process for the analysis of residues; also usable as a concentration unit;high-quality preparative LC-pump, vacuum chamber, stand-alone frequency controlled vacuum pump and vacuum control; 100-110 VAC, 60 Hz. Column, rack, accessoriesare quoted separately.10880 Fully Au<strong>to</strong>mated Sample Preparation System GPC ULTRA; Final volume 5 mL as above, but with high-quality analytical LC-pump10881 Special system for PAH in Oils: Fully Au<strong>to</strong>mated Sample Preparation System GPC ULTRA; preparative LC-pump10836 Online-Combi-Method: EVAporation-GPC-EVAporation covers methods from dried & filtered raw extract <strong>to</strong> GC-Vial10778 Cooling unit for LCTech systems with turntable rack; recommended for all applications with temperature sensitive samples or solvents with low boiling points10518VarioSoft 1.0 - PC-Software <strong>to</strong> run GPC ULTRAPC-Requirements: Windows 98SE or higher; 2 GB Hard Drive; one RS232 Interface (Com-Port), CD-ROM. Computer sold separately.PRODUCT CATALOGPICKERING LABORATORIES10/11
- Page 4 and 5:
TABLE OF CONTENTSINTRODUCTION3 Cust
- Page 6 and 7:
INTRODUCTIONINSTALLATION & TRAINING
- Page 8 and 9:
“A LOT HAS CHANGED SINCE PRODUCIN
- Page 10 and 11:
INSTRUMENTS & HARDWAREFEATURE HIGHL
- Page 12 and 13:
INSTRUMENTS & HARDWARE• Indoor us
- Page 14 and 15:
INSTRUMENTS & HARDWARECRX400 POST-C
- Page 17 and 18:
CHROMATOGRAMS, COLUMNS & GUARDSPick
- Page 19 and 20:
CHROMATOGRAMS, COLUMNS & GUARDSREVE
- Page 21 and 22:
CHROMATOGRAMS, COLUMNS & GUARDS70-M
- Page 23 and 24:
CHROMATOGRAMS, COLUMNS & GUARDSHIGH
- Page 25 and 26:
CHROMATOGRAMS, COLUMNS & GUARDSSTAN
- Page 27 and 28:
CHROMATOGRAMS, COLUMNS & GUARDSSODI
- Page 29 and 30:
CHROMATOGRAMS, COLUMNS & GUARDSHIGH
- Page 31 and 32:
CHROMATOGRAMS, COLUMNS & GUARDSSTAN
- Page 33 and 34:
CHROMATOGRAMS, COLUMNS & GUARDSCARB
- Page 35 and 36: CHROMATOGRAMS, COLUMNS & GUARDSSEPA
- Page 37 and 38: CHROMATOGRAMS, COLUMNS & GUARDSALKI
- Page 39 and 40: CHROMATOGRAMS, COLUMNS & GUARDSCOND
- Page 44 and 45: CHROMATOGRAMS, COLUMNS & GUARDSAFLA
- Page 46 and 47: CHROMATOGRAMS, COLUMNS & GUARDSVOGL
- Page 48 and 49: CHROMATOGRAMS, COLUMNS & GUARDSANAL
- Page 50: “PURE CHEMICALS DO WHAT THEY ARE
- Page 54 and 55: REAGENTS & CHEMICALSSERAPREP & URIP
- Page 56 and 57: REAGENTS & CHEMICALSRESTORECHROMATO
- Page 58 and 59: REAGENTS & CHEMICALSCALIBRATION STA
- Page 60 and 61: ELUANTSCHROMATOGRAPHIC GRADEPickeri
- Page 62 and 63: APPLICATION KITSAmino Acid Analysis
- Page 64 and 65: BECKMAN 6300/7300 COLUMNS & CHEMICA
- Page 66 and 67: REPLACEMENT COMPONENTS, FITTINGS &
- Page 68 and 69: REPLACEMENT COMPONENTS, FITTINGS &
- Page 70 and 71: REPLACEMENT COMPONENTS, FITTINGS &
- Page 72 and 73: REPLACEMENT COMPONENTS, FITTINGS &
- Page 74 and 75: “THE LCTECH STORY”Pickering Lab
- Page 76 and 77: LCTECH / GPC PRODUCT LINEGPC ULTRA
- Page 78 and 79: LCTECH / GPC PRODUCT LINEUtilizing
- Page 80 and 81: LCTECH / GPC PRODUCT LINE• Can be
- Page 82 and 83: LCTECH / GPC PRODUCT LINEFEATURE HI
- Page 84 and 85: LCTECH / GPC PRODUCT LINEFEATURE HI
- Page 88 and 89: LCTECH / GPC PRODUCT LINEEVA IIICON
- Page 90 and 91: LCTECH / MYCOTOXIN PRODUCT LINEUV D
- Page 92 and 93: LCTECH / MYCOTOXIN PRODUCT LINESAMP
- Page 94 and 95: LCTECH / MYCOTOXIN PRODUCT LINEOTAR
- Page 96 and 97: LCTECH / MYCOTOXIN PRODUCT LINEACCE
- Page 98 and 99: “CUSTOMERS REALLY ONLY WANT THE C
- Page 100 and 101: METHOD ABSTRACTS203.1 / MULTI-RESID
- Page 102 and 103: METHOD ABSTRACTS208 / MULTI-RESIDUE
- Page 104 and 105: METHOD ABSTRACTS328 / ANALYSIS OF A
- Page 106 and 107: METHOD ABSTRACTS382 / 70-MIN AMINO
- Page 108 and 109: METHOD ABSTRACTS205 / AMINOGLYCOSID
- Page 110 and 111: METHOD ABSTRACTS102 / ANALYSIS OF B
- Page 112 and 113: METHOD ABSTRACTS120 / BROMATE ANALY
- Page 114 and 115: METHOD ABSTRACTS108 / POST-COLUMN L
- Page 116 and 117: METHOD ABSTRACTS112 / EXPANDED HPLC
- Page 118 and 119: METHOD ABSTRACTS325 / ANALYSIS OF F
- Page 120 and 121: METHOD ABSTRACTS206 continued from
- Page 122 and 123: METHOD ABSTRACTS123 continued from
- Page 124 and 125: METHOD ABSTRACTS105.2 / PARALYTIC S
- Page 126 and 127: METHOD ABSTRACTS104 / POLYETHER ANT
- Page 128 and 129: METHOD ABSTRACTS124 / SULFONAMIDE A
- Page 130 and 131: METHOD ABSTRACTS327 continued from
- Page 132 and 133: GENERAL TERMS & CONDITIONS1 CONTROL
- Page 134: DISTRIBUTORSContinued from previous