LCTECH / MYCOTOXIN PRODUCT LINEACCECLEAN SAMPLE CLEAN-UPACCECLEAN, SAMPLE PREPARATION SYSTEM FOR IAC & SPE COLUMNSCATALOG NO.DESCRIPTION11020 AcceCLEAN, robotic system, up <strong>to</strong> 30 samples in one sequenceSpecial Rack for 3 mL IAC-Cartridge, 3 samples parallel; for 30 mL11262sample vials (V0030) & 4 mL Collection Vial (V0004)Rack* for 1 mL SPE-Cartridge, for usage of 30 mL sample vials11630(V0030), 3 samples parallelRack* for 3 mL SPE-Cartridge, for usage of 30 mL sample vials11631(V0030), 3 samples parallelRack* for 6 mL SPE-Cartridge, for usage of 30 mL sample vials(V0030), 3 samples parallel11632* works only with an eluate rack, please see belowOne of the following eluate racks is needed for 11630-1163211633 ELUATE Rack for 4 mL vials (P/N V0004)11634 ELUATE Rack for 10 mL vials (P/N V0010)CONSUMABLES (VIALS & CAPS) FOR USAGE WITH ACCECLEAN10933 Inlet Cap for 3 mL SPE-columns, 100/bag11629 Inlet Cap for 6/8 mL SPE-columns, 100/bagVials with snap-on-lid, <strong>to</strong>tal volume 30 mLV0030 (Seals & snap-on-lid for s<strong>to</strong>rage only)Packing unit 200/pkVials with snap-on-lid, <strong>to</strong>tal volume 10 mLV0010 (Seals & snap-on-lid for s<strong>to</strong>rage only)Packing unit 100/pkUVE - UV-DERIVATIZERUVE - PHOTOCHEMICAL REACTOR FOR AFLATOXIN ANALYSISCATALOG NO.DESCRIPTION1100-3348 UVE - Pho<strong>to</strong>chemical Reac<strong>to</strong>r for Afla<strong>to</strong>xin Analysis;254 nm lamp; ready <strong>to</strong> use, CE-certification, 240 V, 50 Hz1100-3347 UVE - Pho<strong>to</strong>chemical Reac<strong>to</strong>r for Afla<strong>to</strong>xin Analysis;254 nm lamp; ready <strong>to</strong> use, CE-certification, 90-126 VAC, 50/60 Hz1100-3505 Reac<strong>to</strong>r coil (only for UVE - reac<strong>to</strong>r) ; 1.0 mL, other coil size on request1552-0024 UV replacement lampMINIPHOTOMETER FOR USAGE WITH ELISA-STRIPES(E.G. LCTECH ELISA KITS FOR MYCOTOXIN-ANALYSIS)11689 Pho<strong>to</strong>meter with 450 nm filter & power supply11720 3Ax6 Battery pack boxSAMPLE CLEAN-UP COLUMNSCATALOG NO.DESCRIPTION1705-0003 AflaCLEAN - 25 columns/box1705-0004 OtaCLEAN - 25 columns/box1705-0005 Afla-OtaCLEAN - 25 columns/box1705-0001 SPE Glyphosate clean-up - 50 columns/boxHISTAMINE ANALYSIS KITSHistamine is produced by microbial decomposition of theamino acid histidine and is s<strong>to</strong>red in the cells.In perishable foodstuff like sh, sausages, cheese, wine ormilk the concentration of histamine is an indica<strong>to</strong>r for thefreshness and ultimately for quality of product.The consumption of histamine-containing food can lead <strong>to</strong>serious poisoning. This is why it is absolutely necessary <strong>to</strong>have quick and reliable controls for the histamine concentrationin both food and feed.From an in-situ quick test <strong>to</strong> a complete kit for the analysisof biogenic amines, LCTech and <strong>Pickering</strong> offer reliableand inexpensive <strong>to</strong>ols for the analysis of histamine.CATALOG NO.DESCRIPTION11755 HistaQUICK Fish Meal, 48 samples11754 HistaREAD ELISA Kit, 96 samplesELUFIXCOLUMNS FOR THE H53 METHODAND OTHER FLORISIL® APPLICATIONSThe determination of the hydrocarbon oil index in surface,industrial and process water in compliance with EN ISO9377-2 (H53) is daily routine in many labora<strong>to</strong>ries. Usingintelligent sample preparation can reduce time and costs forthe analysis signicantly.The LCTech Elux columns can be used for all kinds ofsamples. They are delivered fac<strong>to</strong>ry sealed and can beinstantly used without further pre-treatment. The single-usecolumns are lled with 2g, 4g or 10g of activated Florisiland 2g anhydrous sodium sulphate. The use of inert materialslike glass, ber glass and PTFE excludes interactionswith the analytes as well as contaminations.CATALOG NO.937093719372DESCRIPTIONELUFIX Ready-<strong>to</strong>-use columns; 2 g FLORISIL® (150-250 µm) & 2 ganhydrous sodium sulfateELUFIX Ready-<strong>to</strong>-use columns; 4 g FLORISIL® (150-250 µm) & 2 ganhydrous sodium sulfateELUFIX Ready-<strong>to</strong>-use columns; 10 g FLORISIL® (150-250 µm) & 2g anhydrous sodium sulphateELISA KITSCATALOG NO.DESCRIPTION11139 AflaREAD, ELISA Kit (96 well) for the detection of Afla<strong>to</strong>xin B111853AflaREADfast, ELISA Kit (96 well) for determination of Afla<strong>to</strong>xin incorn and peanut based feed11068 OtaREAD, ELISA Kit (96 well) for the detection of Ochra<strong>to</strong>xin A11854OtaREADfast, ELISA Kit (96 well) for the detection of Ota A in corn,coffee, and peanut based feed
LCTECH / MYCOTOXIN PRODUCT LINEELUVACVACUUM MANIFOLD FOR SOLID PHASE EXTRACTIONThe EluVac vacuum manifold allows simultaneous processingup <strong>to</strong> 20 samples under vacuum. It is the ideal solutionfor enriching, concentrating and isolating analytes using solidphase extraction.It is mechanically and chemically robust, exible and can optimallybe used for a wide range of matrices in environmental,food and feed, pharmaceutical and clinical applications.A special highlight: By simply turning the head, you canswitch from the “waste” <strong>to</strong> the “collect” position withoutdisassembling the device.Racks for ten 60 mL and twenty 4 mL as well as for six 100 mLround bot<strong>to</strong>m bottles (NS 29/32) are available for the manifold.For waste, either a 600 mL beaker glass is placed directly inthe system or a central tube leads the waste in<strong>to</strong> an externalcontainer. Thus the EluVac device can also be used for largevolume samples e.g. water or milk.ELUVAC CATALOG INFORMATIONCATALOG NO.DESCRIPTIONEluVac, Vacuum Manifold Package / 20 samples simultaneously,11146 consists of: EluVac - Vacuum Manifold (p/n 11048), sample rack(p/n 11098) and collection rack for 60 mL bottles (p/n 11118)1114711739EluVac, Vacuum Manifold Package / 20 samples simultaneously,consists of: EluVac - Vacuum Manifold (p/n 11048), Probenrack(p/n 11560) collection rack for round bot<strong>to</strong>m bottles for rotaryevapora<strong>to</strong>r (p/n 11112) and 6 pear shaped rotary evapora<strong>to</strong>r bottles(p/n 11106)EluVac, Vacuum Manifold Package / 20 samples simultaneously,- for high sample volume, e.g. water, milk, etc.consists of: EluVac - Vacuum Manifold (p/n 11048), collectionrack for 4 mL-vials (p/n 11105) and 10 SPE-column adapters (p/n11734) and Woulff’s bottle, 10 L (p/n F10000B)11048 EluVac, Vacuum Manifold / 20 samples simultaneously110981111811105Sample Rack for up <strong>to</strong> 10 sample reservoirs (p/ns 10896 or 9370-1/ see below) - on <strong>to</strong>pCollection rack for 60 mL bottles (P/N F060) / 10 samplessimultaneouslyCollection rack for 4 mL Vials (P/N V0004) / 20 samples simultaneouslyfor usage of max 6 pear shaped rotary evapora<strong>to</strong>r flasks:11560 Sample Rack for up <strong>to</strong> 6 sample reservoirs - on <strong>to</strong>p11112111461114711739Collection rack for 100 mL pear shaped rotary evapora<strong>to</strong>r bottles, NS29/32 (P/N 11106)EluVac, Vacuum Manifold Package / 20 samples simultaneously,consists of: EluVac - Vacuum Manifold (p/n 11048), sample rack(p/n 11098) andcollection rack for 60 mL bottles (p/n 11118)EluVac, Vacuum Manifold Package / 20 samples simultaneously,consists of: EluVac - Vacuum Manifold (11048), Probenrack (p/n11560)collection rack for round bottem bottles for rotary evapora<strong>to</strong>r (p/n11112) &6 pear shaped rotary evapora<strong>to</strong>r bottles (p/n 11106)EluVac, Vacuum Manifold Package / 20 samples simultaneously, -for high sample volume , e.g. water, milk etc.consists of: EluVac - Vacuum Manifold (p/n 11048),collection rack for 4 mL-vials (p/n 11105) & 10 SPE-column-adapters(p/n 11734) & Woulff’s bottle, 10 L (p/n F10000B)ELUVAC CATALOG INFORMATIONCATALOG NO.DESCRIPTION11125ME 2C, diaphragm pump, one stage, “Chemistry” RECOMMENDED!230 V, 50-60 Hz, cable, plug & instructions111261112311124ME 2C, diaphragm pump, one stage, “Chemistry” (USA, Korea, Japan)100-120/200-230V / 50-60 Hz, cable, plug & instructionsME 2, diaphragm pump, one stage, “Aluminium”230 V, 50-60 Hz, cable, plug & instructionsME 2, diaphragm pump, one stage, “Aluminium” (USA, Korea, Japan)100-120/200-230V / 50-60 Hz, cable, plug & instructions11043 Adapter ELUFIX-Column <strong>to</strong> Luer (10 pcs./pck) 5 packages and more117349370-1Adapter for SPE-columns (inlet side);connects any size column on<strong>to</strong> a 1, 3, 6 or 15 mL column, with 1.5 maspiration tubing when ordering 10 units or moreReservoir (2 pcs/Pck), made of glass; for sample load (120 mL);labwasher-proof; reusable, includes screwing and PTFE sealSeal fits <strong>to</strong> LCTech glas columns (p/ns 9370, 9371, 9372) whenordering 4 packages and more9373-2 Seals for sample reservoir P/N 9371-1, PTFE, 10 pcs/pck10896Reservoir (2 pcs/Pck), made of glass; for sample load (120 mL);labwasher-proof; reusable, includes screwing and PTFE sealSeal fits <strong>to</strong> immunoaffinity columns when ordering 4 packages and more10909 Seals for sample reservoir P/N 10896, PTFE, 10 pcs/pck10081F10000BClamp, 3 fingers with rubber (for usage with reservoir) 5 packagesand moreBottle, coated, 10 L, with special screw cap and 2 m tubingMINERAL OIL HYDROCARBON INDEX(H53-METHOD) ELUFIX COLUMNSACCECLEAN, SAMPLE PREPARATION SYSTEM FOR IAC- & SPE COLUMNSCATALOG NO.DESCRIPTION9370 ELUFIX Ready-<strong>to</strong>-use columns; made of glass for method H53; lotcertification enclosed; suitability check and result performance incompliance with EN ISO 9377-2; Filling material: 2 g FLORISIL®(150 - 250 µm) & 2 g anhydrous sodium sulfate welded in strips offive; 10 strips per package4 packages and more (200 columns)8 packages and more (400 columns)16 packages and more (800 columns)9371 ELUFIX Ready-<strong>to</strong>-use columns; made of glass for method H53;lot certificate enclosed; suitability check and result performance incompliance with EN ISO 9377-2Filling material: 4 g FLORISIL® (150 - 250 µm) & 2 g anhydroussodium sulfate welded in strips of five; 10 strips per package4 packages and more (200 columns)8 packages and more (400 columns)16 packages and more (800 columns)9372 ELUFIX Ready-<strong>to</strong>-use columns; made of glass for method H53;lot certificate enclosed; suitability check and result performance incompliance with EN ISO 9377-2Filling material: 10 g FLORISIL® (150 - 250 µm) & 2 g anhydroussodium sulfate welded in strips of three; 10 strips per package4 packages and more (120 columns)16 packages and more (460 columns)32 packages and more (960 columns)10374 Empty Glass Column, Fiolax, 105 mm length x 17 mm diam.;100 pcs/pck4 packages and more11156 Empty Glass Column, Fiolax, 180 mm length x 17 mm diam.;100 pcs/pck4 packages and more10230 Glass Fiber Filters, Diameter 15 mm (100 pcs/box)ACCESSORIES FOR ELUVAC11106 Rotary evapora<strong>to</strong>r bottle, NS 29/32, 100 mL, pear shaped95PRODUCT CATALOGPICKERING LABORATORIES10/11
- Page 4 and 5:
TABLE OF CONTENTSINTRODUCTION3 Cust
- Page 6 and 7:
INTRODUCTIONINSTALLATION & TRAINING
- Page 8 and 9:
“A LOT HAS CHANGED SINCE PRODUCIN
- Page 10 and 11:
INSTRUMENTS & HARDWAREFEATURE HIGHL
- Page 12 and 13:
INSTRUMENTS & HARDWARE• Indoor us
- Page 14 and 15:
INSTRUMENTS & HARDWARECRX400 POST-C
- Page 17 and 18:
CHROMATOGRAMS, COLUMNS & GUARDSPick
- Page 19 and 20:
CHROMATOGRAMS, COLUMNS & GUARDSREVE
- Page 21 and 22:
CHROMATOGRAMS, COLUMNS & GUARDS70-M
- Page 23 and 24:
CHROMATOGRAMS, COLUMNS & GUARDSHIGH
- Page 25 and 26:
CHROMATOGRAMS, COLUMNS & GUARDSSTAN
- Page 27 and 28:
CHROMATOGRAMS, COLUMNS & GUARDSSODI
- Page 29 and 30:
CHROMATOGRAMS, COLUMNS & GUARDSHIGH
- Page 31 and 32:
CHROMATOGRAMS, COLUMNS & GUARDSSTAN
- Page 33 and 34:
CHROMATOGRAMS, COLUMNS & GUARDSCARB
- Page 35 and 36:
CHROMATOGRAMS, COLUMNS & GUARDSSEPA
- Page 37 and 38:
CHROMATOGRAMS, COLUMNS & GUARDSALKI
- Page 39 and 40:
CHROMATOGRAMS, COLUMNS & GUARDSCOND
- Page 44 and 45:
CHROMATOGRAMS, COLUMNS & GUARDSAFLA
- Page 46 and 47: CHROMATOGRAMS, COLUMNS & GUARDSVOGL
- Page 48 and 49: CHROMATOGRAMS, COLUMNS & GUARDSANAL
- Page 50: “PURE CHEMICALS DO WHAT THEY ARE
- Page 54 and 55: REAGENTS & CHEMICALSSERAPREP & URIP
- Page 56 and 57: REAGENTS & CHEMICALSRESTORECHROMATO
- Page 58 and 59: REAGENTS & CHEMICALSCALIBRATION STA
- Page 60 and 61: ELUANTSCHROMATOGRAPHIC GRADEPickeri
- Page 62 and 63: APPLICATION KITSAmino Acid Analysis
- Page 64 and 65: BECKMAN 6300/7300 COLUMNS & CHEMICA
- Page 66 and 67: REPLACEMENT COMPONENTS, FITTINGS &
- Page 68 and 69: REPLACEMENT COMPONENTS, FITTINGS &
- Page 70 and 71: REPLACEMENT COMPONENTS, FITTINGS &
- Page 72 and 73: REPLACEMENT COMPONENTS, FITTINGS &
- Page 74 and 75: “THE LCTECH STORY”Pickering Lab
- Page 76 and 77: LCTECH / GPC PRODUCT LINEGPC ULTRA
- Page 78 and 79: LCTECH / GPC PRODUCT LINEUtilizing
- Page 80 and 81: LCTECH / GPC PRODUCT LINE• Can be
- Page 82 and 83: LCTECH / GPC PRODUCT LINEFEATURE HI
- Page 84 and 85: LCTECH / GPC PRODUCT LINEFEATURE HI
- Page 86 and 87: LCTECH / GPC PRODUCT LINE3Intensity
- Page 88 and 89: LCTECH / GPC PRODUCT LINEEVA IIICON
- Page 90 and 91: LCTECH / MYCOTOXIN PRODUCT LINEUV D
- Page 92 and 93: LCTECH / MYCOTOXIN PRODUCT LINESAMP
- Page 94 and 95: LCTECH / MYCOTOXIN PRODUCT LINEOTAR
- Page 98 and 99: “CUSTOMERS REALLY ONLY WANT THE C
- Page 100 and 101: METHOD ABSTRACTS203.1 / MULTI-RESID
- Page 102 and 103: METHOD ABSTRACTS208 / MULTI-RESIDUE
- Page 104 and 105: METHOD ABSTRACTS328 / ANALYSIS OF A
- Page 106 and 107: METHOD ABSTRACTS382 / 70-MIN AMINO
- Page 108 and 109: METHOD ABSTRACTS205 / AMINOGLYCOSID
- Page 110 and 111: METHOD ABSTRACTS102 / ANALYSIS OF B
- Page 112 and 113: METHOD ABSTRACTS120 / BROMATE ANALY
- Page 114 and 115: METHOD ABSTRACTS108 / POST-COLUMN L
- Page 116 and 117: METHOD ABSTRACTS112 / EXPANDED HPLC
- Page 118 and 119: METHOD ABSTRACTS325 / ANALYSIS OF F
- Page 120 and 121: METHOD ABSTRACTS206 continued from
- Page 122 and 123: METHOD ABSTRACTS123 continued from
- Page 124 and 125: METHOD ABSTRACTS105.2 / PARALYTIC S
- Page 126 and 127: METHOD ABSTRACTS104 / POLYETHER ANT
- Page 128 and 129: METHOD ABSTRACTS124 / SULFONAMIDE A
- Page 130 and 131: METHOD ABSTRACTS327 continued from
- Page 132 and 133: GENERAL TERMS & CONDITIONS1 CONTROL
- Page 134: DISTRIBUTORSContinued from previous