DESIGN PRINCIPLES AND CALCULATIONS<br />
TABLE 6: Concentrated Loads with 1 251 mm (4’-1 1/4”) Joist Spacing<br />
f’ c = 20 MPa (3 000 psi), F y = 400 MPa (60 000 psi) for Wire Mesh<br />
CONCENTRATED SLAB MESH SIZE SPECIAL REMARKS<br />
LOAD THICKNESS 152 x 152 (6 x 6) (See fig. 1)<br />
MW18.7 x MW18.7 Extra layer @ � and �<br />
70 mm (2 3/4”)<br />
OFFICE BUILDING<br />
to<br />
90 mm (3<br />
(6/6)<br />
MW18.7 x MW18.7 Single layer throughout No<br />
1/2”)<br />
(6/6)<br />
MW25.7 x MW25.7<br />
but S1 ≤ 1 050 mm<br />
Single layer throughout<br />
“chairs” on<br />
Top chord<br />
9 kN on (4/4)<br />
750 mm x 750 mm<br />
100 mm (4”)<br />
to<br />
125 mm (5”)<br />
MW25.7 x MW25.7<br />
(4/4)<br />
MW13.3 x MW13.3 (8/8)<br />
or MW18.7 x MW18.7 (6/6)<br />
Single layer throughout<br />
Double layers throughout<br />
MW18.7 x MW18.7<br />
(6/6)<br />
Double layers throughout<br />
PASSENGER CAR * MW25.7 x MW25.7 Extra layer @ � No<br />
90 mm (3<br />
(4/4) “chairs” on<br />
1/2”)<br />
11 kN on<br />
750 mm x 750 mm<br />
to<br />
115 mm (4<br />
MW25.7 x MW25.7<br />
(4/4)<br />
Single layer throughout<br />
but S1 ≤ 1 050 mm<br />
Top chord<br />
1/2”)<br />
MW13.3 x MW13.3 Double layers throughout<br />
plus 50 mm asphalt (8/8) + Extra layer @ �<br />
MW13.3 x MW13.3<br />
(8/8)<br />
Double layers throughout<br />
but S1 ≤ 1 050 mm<br />
MW18.7 x MW18.7 Double layers throughout No<br />
PASSENGER CAR *<br />
90 mm (3 1/2”)<br />
18 kN on<br />
750 mm x 750 mm<br />
to<br />
115 mm (4<br />
(6/6)<br />
MW25.7 x MW25.7 Extra layer @ � and �<br />
“chairs” on<br />
Top chord<br />
1/2”)<br />
plus 50 mm asphalt<br />
(4/4)<br />
MW25.7 x MW25.7<br />
(4/4)<br />
Single layer throughout<br />
but S1 ≤ 1 050 mm<br />
* See CAN3-S413-94 for Parking Structures Design for more information.<br />
TABLE 7: Concentrated Loads with 1 555 mm (5’-1 1/4”) Joist Spacing<br />
f’ c = 20 MPa (3 000 psi), F y = 400 MPa (60 000 psi) for Wire Mesh<br />
CONCENTRATED SLAB MESH SIZE SPECIAL REMARKS<br />
LOAD THICKNESS 152 x 152 (6 x 6) (See fig. 4)<br />
OFFICE BUILDING<br />
9 kN on<br />
70 mm (2<br />
MW25.7 x MW25.7 Extra layer @ �<br />
3/<br />
750 mm x 750 mm<br />
4”)<br />
to<br />
100 mm (4”)<br />
(4/4)<br />
MW18.7 x MW18.7<br />
(6/6)<br />
Double layers throughout<br />
PASSENGER CAR *<br />
90 mm (3 1/<br />
11 kN on<br />
750 mm x 750 mm<br />
2”)<br />
to<br />
115 mm (4<br />
MW18.7 x MW18.7<br />
(6/6)<br />
Double layers throughout<br />
but S1 ≤ 1 050 mm<br />
1/<br />
plus 50 mm asphalt 2”)<br />
MW25.7 x MW25.7<br />
(4/4)<br />
Single layer throughout<br />
+ Extra layer @ � and �<br />
PASSENGER CAR *<br />
90 mm (3 1/<br />
MW18.7 x MW18.7 Double layers throughout<br />
2”)<br />
18 kN on<br />
to<br />
(6/6) + Extra layer @ � and �<br />
750 mm x 750 mm<br />
115 mm (4 1/<br />
MW25.7 x MW25.7 Double layers throughout<br />
plus 50 mm asphalt 2”)<br />
(4/4)<br />
* See CAN3-S413-94 for Parking Structures Design for more information.<br />
NOTE: For other configurations, please contact your <strong>Hambro</strong> representative.<br />
No<br />
“chairs” on<br />
Top chord<br />
No<br />
“chairs” on<br />
Top chord<br />
No<br />
“chairs” on<br />
Top chord<br />