SECTION 31 - FLANGE HANGER FOR BEAM AND WALL<br />
SECTION 29 - MINI-JOIST WITH HANGER PLATE AT CORRIDOR<br />
SLAB THICKNESS 130 mm (5 1/4”)<br />
REINFORCED STEEL BY THE CONSULTING ENGINEER<br />
25 @ 300 mm (1” @ 12”)<br />
5 mm ( 3/16”)<br />
90 mm (3 1/ 2”) MIN.<br />
FOR 100 mm (4”) SHOE (TYP.)<br />
300 mm<br />
(12”)<br />
90 mm (3 1/2”)<br />
MIN. FOR<br />
100 mm (4”)<br />
SHOE (TYP.)<br />
WELDED WIRE-MESH<br />
TOP OF<br />
BEARING<br />
T + 6 mm ( 1 /4”)<br />
300 mm<br />
(12”)<br />
WELDED<br />
WIRE<br />
MESH<br />
NO SHOE<br />
(U.N.O.)<br />
ON MINI JOIST<br />
ROLLBAR<br />
NOMINAL<br />
JOIST DEPTH SLAB<br />
(D) (T)<br />
TYPICAL DETAILS<br />
CEILING EXTENSION<br />
FLANGE HANGER (TYPE F.H)<br />
HANGER PLATE<br />
FOR THICKER SLAB<br />
CORRIDOR<br />
STEEL BEAM, STEEL STUD WALL, WOOD STUD WALL,<br />
MASONRY WALL OR CONCRETE WALL<br />
SOLID MASONRY WALL,<br />
ACCORDING TO THE SPECIFICATIONS OF THE CONSULTING ENGINEER<br />
(FILL THE MASONRY BLOCK WITH MORTAR, UNDER THE JOIST SHOE)<br />
REBAR<br />
(IF REQUIRED BY THE<br />
CONSULTING ENGINEER)<br />
T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />
SECTION 32 - FLANGE HANGER FOR INSULATED CONCRETE FORM<br />
SECTION 30 - HEADER SUPPORT<br />
WELDED WIRE-MESH<br />
5 mm ( 3/16”) 20 mm ( 3 /4”)<br />
20 mm ( 3/4”) Ø HOLES<br />
AT 600 mm (24”) C/C<br />
FOR ANCHORED<br />
(T)<br />
SLAB<br />
(1 1/2”)<br />
39 mm<br />
FLANGE HANGER<br />
(TYPE M.H)<br />
HEADER BEAM<br />
ROLLBAR<br />
REINFORCED INSULATED CONCRETE WALL<br />
IF THERE IS A JOIST SITTING ON THE HEADER BEAM,<br />
THE DIMENSION 39 mm (1 1/2”) WILL BECOME 45 mm (1 3/4”) AND “(T)”<br />
WILL BECOME “T + 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS”<br />
9