SECTION 7 - JOIST BEARING ON CONCRETE WALL<br />

WITH INSULATED FORMS<br />

SECTION 5 - JOIST BEARING ON MASONRY OR CONCRETE WALL<br />

NO ANCHORED PLATE OR MECHANICAL FASTENER IS<br />

REQUIRED TO FIX THE JOIST TO THE CONCRETE WALL.<br />

90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />

90 mm (3 1/2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />

NOTCH RIGID INSULATION<br />

NO ANCHORED PLATE<br />

OR MECHANICAL<br />

FASTENER IS REQUIRED<br />

TO FIX THE JOIST TO<br />

THE CONCRETE WALL.<br />

WELDED WIRE-MESH<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING<br />

ENGINEER)<br />

WELDED WIRE-MESH<br />

(D) (T)<br />

SLAB<br />

(T)<br />

SLAB<br />

(D)<br />

NOMINAL<br />

JOIST DEPTH<br />

TOP OF BEARING<br />

T + 6 mm ( 1/4”)<br />

NOMINAL<br />

JOIST DEPTH<br />

TOP OF BEARING<br />

T + 6 mm ( 1 /4”)<br />

TYPICAL DETAILS<br />

CEILING EXTENSION<br />

CEILING EXTENSION<br />

SOLID MASONRY WALL OR REINFORCED CONCRETE WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

(FILL THE MASONRY BLOCK WITH MORTAR, UNDER THE JOIST SHOE)<br />

REINFORCED INSULATED CONCRETE WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING ENGINEER)<br />

T+ 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS<br />

T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />

SECTION 8 - JOISTS BEARING ON CONCRETE WALL<br />

WITH INSULATED FORMS<br />

SECTION 6 - JOISTS BEARING ON MASONRY OR CONCRETE WALL<br />

NO ANCHORED PLATE OR MECHANICAL FASTENER IS<br />

REQUIRED TO FIX THE JOIST TO THE CONCRETE WALL.<br />

90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />

90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />

WELDED WIRE-MESH<br />

NOTCH RIGID INSULATION (TYP.)<br />

WELDED WIRE-MESH<br />

NO ANCHORED PLATE<br />

OR MECHANICAL FASTENER IS<br />

REQUIRED TO FIX THE JOIST<br />

TO THE CONCRETE WALL.<br />

(T)<br />

SLAB<br />

(T)<br />

SLAB<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

CEILING EXTENSION<br />

CEILING EXTENSION<br />

T + 6 mm ( 1/4”)<br />

TOP OF BEARING<br />

CEILING EXTENSION<br />

REINFORCED INSULATED CONCRETE<br />

WALL, ACCORDING TO THE<br />

SPECIFICATIONS OF THE<br />

CONSULTING ENGINEER<br />

CEILING EXTENSION<br />

TOP OF BEARING<br />

T + 6 mm ( 1 /4”)<br />

SOLID MASONRY WALL OR REINFORCED<br />

CONCRETE WALL, ACCORDING TO THE<br />

SPECIFICATIONS OF THE CONSULTING ENGINEER<br />

REBAR<br />

(IF REQUIRED BY THE<br />

CONSULTING ENGINEER)<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING ENGINEER)<br />

(FILL THE MASONRY BLOCK WITH MORTAR, UNDER THE JOIST SHOE)<br />

T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />

T + 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS<br />