SECTION 15 - JOISTS BEARING ON A WOOD STUD WALL<br />
SECTION 13 - JOIST BEARING ON AN EXTERIOR STEEL STUD WALL<br />
90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
JOIST SHOE ANCHORED TO PLANK<br />
WITH SCREWS OR NAILS<br />
WELDED WIRE-MESH<br />
40 mm (1<br />
WELDED WIRE-MESH<br />
1 /2”)<br />
5 mm ( 3/16”)<br />
SLAB<br />
(T)<br />
(T)<br />
SLAB<br />
(D)<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
CEILING EXTENSION<br />
CEILING EXTENSION<br />
TOP OF BEARING<br />
T + 6 mm ( 1 /4”)<br />
NOMINAL<br />
JOIST DEPTH<br />
TOP OF BEARING<br />
T + 6 mm ( 1 /4”)<br />
TYPICAL DETAILS<br />
THE WOOD WALL AND THE TOP PLATE<br />
CAPACITY, ACCORDING TO THE<br />
SPECIFICATIONS OF THE<br />
CONSULTING ENGINEER<br />
NOTE; STAGGERED JOISTS<br />
CEILING EXTENSION<br />
THE METAL STUD AND THE TOP PLATE CAPACITY,<br />
ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />
T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />
T + 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS<br />
SECTION 16 - EXPANSION JOINT AT INTERMEDIATE FLOOR (MASONRY WALL)<br />
SECTION 14 - JOIST BEARING ON A WOOD STUD WALL<br />
ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />
90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
FIBRE BOARD 12 mm ( 1 /2”)<br />
DO NOT WELD THE SHOE ON THE ANGLE<br />
ANGLE ANCHORED TO THE MASONRY<br />
WALL ACCORDING TO THE<br />
SPECIFICATIONS OF THE<br />
CONSULTING ENGINEER<br />
JOIST SHOE ANCHORED TO PLANK WITH SCREWS OR NAILS<br />
WELDED WIRE-MESH<br />
WELDED WIRE-MESH<br />
(D) (T)<br />
SLAB<br />
T + 6 mm (<br />
TOP OF BEARING<br />
1/4”)<br />
NOMINAL<br />
JOIST DEPTH SLAB<br />
(D) (T)<br />
REBAR (IF REQUIRED BY THE<br />
CONSULTING ENGINEER)<br />
NOMINAL<br />
JOIST DEPTH<br />
TOP OF BEARING<br />
T + 6 mm ( 1/4”)<br />
CEILING EXTENSION<br />
SUPPORT ANGLE, ACCORDING TO THE<br />
SPECIFICATIONS OF THE CONSULTING ENGINEER.<br />
SOLID MASONRY WALL,<br />
ACCORDING TO THE<br />
SPECIFICATIONS OF THE<br />
CONSULTING ENGINEER<br />
CEILING EXTENSION<br />
TEMPORARY SUPPORT UNDER EACH JOIST AND<br />
EACH END UNTIL ALL FLOORS HAVE BEEN POURED.<br />
(PROVIDED AND DESIGNED BY OTHERS)<br />
THE WOOD WALL AND THE TOP PLATE CAPACITY,<br />
ACCORDING TO THE SPECIFICATIONS OF THE CONSULTING ENGINEER<br />
T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />
T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />