SECTION 7 - JOISTS BEARING ON CONCRETE WALL<br />
WITH INSULATED FORM<br />
SECTION 5 - JOISTS BEARING ON MASONRY OR CONCRETE WALL<br />
90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
90 mm (3 1/2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
NOTCH RIGID INSULATION (TYP.)<br />
NOMINAL<br />
SLAB<br />
(T)<br />
STEEL DECK<br />
WELDED WIRE-MESH<br />
STEEL DECK<br />
WELDED WIRE-MESH<br />
NOMINAL<br />
SLAB<br />
(T)<br />
TOTAL<br />
SLAB<br />
TOTAL<br />
SLAB<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
CEILING EXTENSION<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
CEILING EXTENSION<br />
TYPICAL DETAILS<br />
CEILING EXTENSION<br />
CEILING EXTENSION<br />
SOLID MASONRY WALL OR REINFORCED<br />
CONCRETE WALL, ACCORDING TO THE<br />
SPECIFICATIONS OF THE CONSULTING ENGINEER<br />
(FILL THE MASONRY BLOCK WITH MORTAR,<br />
UNDER THE JOIST SHOE)<br />
REBAR<br />
(IF REQUIRED BY THE<br />
CONSULTING ENGINEER)<br />
REINFORCED INSULATED CONCRETE WALL<br />
ACCORDING TO THE SPECIFICATIONS,<br />
OF THE CONSULTING ENGINEER<br />
REBAR<br />
(IF REQUIRED BY THE<br />
CONSULTING ENGINEER)<br />
SECTION 8 - JOIST BEARING ON STEEL BEAM<br />
SECTION 6 - JOIST BEARING ON CONCRETE WALL<br />
WITH INSULATED FORM<br />
65 mm (2 1 /2”) MIN. FOR 75 mm (3”)<br />
OR 100 mm (4”) SHOE (TYP.)<br />
90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
NOMINAL<br />
SLAB<br />
(T)<br />
40 mm (1 1 /2”)<br />
5 mm ( 3 /16”)<br />
STEEL DECK<br />
WELDED<br />
WIRE-MESH<br />
NOMINAL<br />
SLAB<br />
(T)<br />
STEEL<br />
DECK<br />
WELDED<br />
WIRE-MESH<br />
TOTAL<br />
SLAB<br />
TOTAL<br />
SLAB<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
CEILING EXTENSION<br />
CEILING EXTENSION<br />
STEEL BEAM, ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER (U.N.O)<br />
POUR STOP<br />
(BY OTHERS)<br />
NOTCH RIGID INSULATION<br />
REINFORCED INSULATED CONCRETE WALL, ACCORDING<br />
TO THE SPECIFICATIONS OF THE CONSULTING ENGINEER<br />
REBAR<br />
(IF REQUIRED BY THE<br />
CONSULTING ENGINEER)<br />
15