SECTION 15 - EXPANSION JOINT AT ROOF (AT MASONRY WALL)<br />
SECTION 13 - JOISTS BEARING ON WOOD STUD WALL<br />
FIBRE BOARD 12 mm (<br />
DO NOT WELD THE SHOE<br />
ON THE EMBEDED MATERIAL<br />
STEEL DECK<br />
1/2”)<br />
90 mm (3 1/2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
12 mm ( 1 /2”)Ø ROD x 600 mm (24”)<br />
@ 600 mm (24”) c/c.<br />
GREASE OR WRAP THIS END<br />
OF ROD WITH BUILDING PAPER<br />
SHOE ANCHORED TO THE PLANK<br />
WITH SCREWS OR NAILS<br />
90 mm (3 1/2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />
NOMINAL<br />
SLAB<br />
(T)<br />
STEEL DECK<br />
WELDED WIRE-MESH<br />
NOMINAL<br />
SLAB<br />
(T)<br />
WELDED WIRE-MESH<br />
TOTAL<br />
SLAB<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
NOMINAL<br />
JOIST DEPTH<br />
(D) TOTAL<br />
SLAB<br />
T + 38 mm (1 1/2”)<br />
TOP OF BEARING<br />
TYPICAL DETAILS<br />
CEILING EXTENSION<br />
SOLID MASONRY WALL,<br />
ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />
(FILL THE MASONRY BLOCK WITH MORTAR,<br />
UNDER THE HAMBRO SHOE)<br />
CEILING EXTENSION<br />
CEILING EXTENSION<br />
CEILING EXTENSION<br />
REBAR<br />
(IF REQUIRED BY THE<br />
CONSULTING ENGINEER<br />
THE WOOD WALL AND THE TOP PLATE<br />
CAPACITY, ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />
NOTE: STAGGERED JOIST<br />
SECTION 16 - EXPANSION JOINT AT FLOORS (AT STEEL BEAM)<br />
SECTION 14 - EXPANSION JOINT AT INTERMEDIATE FLOORS<br />
(AT MASONRY WALL)<br />
40 mm<br />
OR<br />
1 5 mm<br />
1 /2”<br />
3 /16”<br />
ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />
ANGLE ANCHORED TO<br />
THE MASONRY WALL, ACCORDING<br />
TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />
NOMINAL<br />
SLAB<br />
(T)<br />
FIBRE BOARD 12 mm (<br />
DO NOT WELD THE<br />
SHOE ON THE ANGLE<br />
STEEL DECK<br />
1/2”)<br />
65 mm (2 1 /2”) MIN. FOR 75 mm (3”)<br />
OR 100 mm (4”) SHOE (TYP.)<br />
WELDED WIRE-MESH<br />
NOMINAL<br />
SLAB<br />
(T)<br />
FIBRE BOARD 12 mm (<br />
STEEL DECK<br />
1/2”)<br />
DO NOT WELD THE SHOE<br />
ON THE ANGLE<br />
WELDED WIRE-MESH<br />
TOTAL<br />
SLAB<br />
SLAB<br />
NOMINAL<br />
JOIST DEPTH<br />
(D)<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
T + 38 mm (1 1 /2”)<br />
TOP OF BEARING<br />
NOMINAL<br />
JOIST DEPTH<br />
(D) TOTAL<br />
REBAR<br />
(IF REQUIRED BY THE<br />
CONSULTING ENGINEER)<br />
CEILING EXTENSION<br />
STIFFENER (IF REQUIRED)<br />
CEILING EXTENSION<br />
CEILING EXTENSION<br />
SUPPORT ANGLE, ACCORDING TO THE<br />
SPECIFICATIONS OF THE CONSULTING ENGINEER<br />
STEEL BEAM, ACCORDING TO<br />
THE SPECIFICATIONS OF THE<br />
CONSULTING ENGINEER (U.N.O)<br />
SUPPORT ANGLE, ACCORDING TO THE<br />
SPECIFICATIONS OF THE CONSULTING ENGINEER<br />
TEMPORARY SUPPORT UNDER EACH JOIST AND<br />
EACH END UNTIL ALL FLOORS HAVE BEEN POURED<br />
(PROVIDED AND DESIGNED BY OTHERS)<br />
SOLID MASONRY WALL,<br />
ACCORDING TO THE SPECIFICATIONS<br />
OF THE CONSULTING ENGINEER<br />