SECTION 23 - JOIST PARALLEL TO CONCRETE WALL WITH INSULATED FORMS<br />

SECTION 21 - JOIST PARALLEL TO EXPANSION JOINT<br />

FIBRE BOARD 12 mm ( 1 /2”)<br />

2 LAYERS OF ROOFING PAPER<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING ENGINEER)<br />

WELDED WIRE-MESH<br />

WELDED WIRE-MESH<br />

SLAB<br />

(T)<br />

(T)<br />

SLAB<br />

TOP OF BEARING<br />

T + 6 mm ( 1/4”)<br />

FLANGE HANGER<br />

(FIXED, ED-D500)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

T + 6 mm ( 1/4”)<br />

TOP OF BEARING<br />

FLANGE<br />

HANGER<br />

(FIXED,<br />

SEE ED-D500)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING<br />

ENGINEER)<br />

SOLID MASONRY WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

REINFORCED INSULATED CONCRETE WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

TYPICAL DETAILS<br />

T + 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS<br />

(NOTE: IF THE FLANGE HANGER IS NOT USED, TOP OF BEARING = T + 20 mm ( 3 /4”))<br />

T + 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS<br />

(NOTE: IF THE FLANGE HANGER IS NOT USED, TOP OF BEARING = T + 20 mm ( 3 /4”))<br />

SECTION 24 - JOIST PARALLEL TO A BEAM<br />

SECTION 22 - JOIST PARALLEL TO A MASONRY OR CONCRETE WALL<br />

WELDED WIRE-MESH<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING ENGINEER)<br />

WELDED-WIRE-MESH<br />

SLAB<br />

(T)<br />

(T)<br />

SLAB<br />

TOP OF<br />

BEARING<br />

T + 6 mm ( 1 /4”)<br />

FLANGE HANGER<br />

(FIXED, SEE ED-D500)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

TOP OF BEARING<br />

T + 6 mm ( 1 /4”)<br />

FLANGE HANGER<br />

(FIXED, SEE ED-D500)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

STEEL BEAM,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER (U.N.O)<br />

SOLID MASONRY WALL<br />

OR REINFORCED CONCRETE WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

T + 6 mm ( 1/4”) = SLAB THICKNESS + SHOE THICKNESS<br />

(NOTE: IF THE FLANGE HANGER IS NOT USED, TOP OF BEARING = T + 20 mm ( 3 /4”))<br />

T + 6 mm ( 1 /4”) = SLAB THICKNESS + SHOE THICKNESS<br />

(NOTE: IF THE FLANGE HANGER IS NOT USED, TOP OF BEARING = T + 20 mm ( 3 /4”))<br />