5.2 MD2000 ® SERIES<br />

5.2.1 DESCRIPTION<br />

<strong>Hambro</strong> MD2000 Series features a top chord made of<br />

2 pieces welded together in order to receive the metal deck<br />

each side. The open web is made with mild steel rods and<br />

a wide range of bottom chord. The steel deck is used as<br />

formwork only during pouring.<br />

5.2.2 MATERIALS<br />

The <strong>Hambro</strong> top chord acts as a continuous shear connector.<br />

Bottom chord angles and web members are hot or cold<br />

rolled sections, minimum yield Fy = 380 MPa (55 ksi) and<br />

350 MPa (50 ksi) for rods.<br />

5.2.3 WEB GEOMETRY<br />

The web geometry is exactly the same of D500TM presented in page 33.<br />

5.2.4 JOIST SPACING<br />

Between 300 mm (1’-0”) and 1 450 mm (4’-9”) according<br />

to the steel deck capacity in single span. The standard<br />

spacing is 1 220 mm (4’-0”).<br />

5.2.5 SPAN AND DEPTH<br />

Span: Up to 13 100 mm (43’-0”)<br />

Depth: Between 200 mm (8”) and 600 mm (24”)<br />

2<br />

PRODUCT INFORMATION<br />

Slab<br />

Thickness<br />

MD2000 Joist<br />

Depth<br />

Top of Slab<br />

Fig. 21<br />

5.2.6 SLAB DESIGN<br />

The minimum “TOTAL SLAB THICKNESS” is 110 mm<br />

(4 1 /4”) including the steel deck. See figure 21 for more<br />

information.<br />

5.2.7 STEEL DECK<br />

The steel deck used is P-3606, 22 GA (0.76 mm). The depth<br />

is 38 mm (1 1 /2”). The deck must be designed in single span<br />

(spacing between joist). For more information, see the<br />

Canam brochure about it. The deck must be connected on<br />

the MD2000 top chord by welding or screwing.<br />

5.2.8 INSTALLATION<br />

Installation shall be in accordance with the manufacturer’s<br />

recommendations and the erection drawings.<br />

5.2.9 PERMANENT BRIDGING<br />

Bridging must be installed as specified on erection<br />

drawings.<br />

5.2.10 TYPICAL DETAILS<br />

See typical details section page 13 to 22.<br />

38 mm<br />

(1 1 /2”)<br />

38 mm (1 1 /2”) Steel Deck<br />

(22 GA. MIN.)<br />

Total slab thickness = Slab thickness + 38 mm (1 1 /2”)<br />

Total slab thickness ≥ 110 mm (4 1 /4”)<br />

Slab thickness ≥ 70 mm (2 3 /4”)<br />

Total slab<br />

thickness